Guide
Home backup during outages
A portable power station can cover a short list of plug-in devices. It is not a substitute for a permanently installed standby generator or a home battery sized for an entire service panel. This page is a planning method. It is not electrical advice and it is not a claim that any model will keep your house running.
Start with one circuit’s worth of plugs
List devices you would actually move onto the station:
- A refrigerator’s running watts are often far below the watts it draws for a second when the compressor starts. The label or manual may show running watts and a locked-rotor or surge figure. If it does not, this site cannot tell you whether a station will start that fridge.
- A Wi-Fi router is often near 10 W and runs continuously, so a small station can cover it for many hours if nothing else is on.
- A few LED bulbs or a lamp are a small, steady load. Add them in the calculator instead of guessing “the lights.”
- Microwaves, kettles, space heaters, and hair dryers are short, heavy loads. A 1,500 W heater can exceed the continuous output of many mid-size stations even when the watt-hour capacity looks large.
Runtime for a cycling fridge depends on the duty cycle you enter. A 40% duty cycle is a placeholder so the field is not stuck at 100%. Measure your own fridge if the outage plan depends on it. The estimate also ignores inverter idle draw, so a very light load can be shorter in practice than the math suggests.
Stations at or above 1,000 Wh and 1,500 W
The filter below is only a way to scan this dataset. It is not a recommendation, and it does not mean each model can run a refrigerator.
- EcoFlow DELTA 2 — 1024 Wh , 1800 W continuous , 2700 W surge published
- EcoFlow DELTA 3 Plus — 1024 Wh , 1800 W continuous , 3600 W surge published
- BLUETTI Elite 100 V2 — 1024 Wh , 1800 W continuous , surge not published on the page we checked
- Anker SOLIX C1000 Gen 2 — 1024 Wh , 2000 W continuous , 3000 W surge published
- DJI Power 1000 — 1024 Wh , 2200 W continuous , 4400 W surge published
- Pecron E1000LFP — 1024 Wh , 1800 W continuous , 3000 W surge published
- Anker SOLIX C1000 — 1056 Wh , 1800 W continuous , surge not published on the page we checked
- Jackery Explorer 1000 v2 — 1070 Wh , 1500 W continuous , 3000 W surge published
- BLUETTI AC180 — 1152 Wh , 1800 W continuous , 2700 W surge published
- Jackery Explorer 1000 Plus — 1264.64 Wh , 2000 W continuous , 4000 W surge published
- BLUETTI AC180P — 1440 Wh , 1800 W continuous , 2700 W surge published
- Goal Zero Yeti 1500 — 1505.28 Wh , 2000 W continuous , 3600 W surge published
- Pecron E1500LFP — 1536 Wh , 2200 W continuous , 4400 W surge published
- Jackery Explorer 2000 v2 — 2042 Wh , 2200 W continuous , 4400 W surge published
- Jackery Explorer 2000 Plus — 2042.8 Wh , 3000 W continuous , 6000 W surge published
- EcoFlow DELTA 2 Max — 2048 Wh , 2400 W continuous , 4800 W surge published
- Jackery HomePower 2000 Plus v2 — 2048 Wh , 2400 W continuous , surge not published on the page we checked
- BLUETTI AC200L — 2048 Wh , 2400 W continuous , surge not published on the page we checked
- Anker SOLIX C2000 Gen 2 — 2048 Wh , 2400 W continuous , 4000 W surge published
- Anker SOLIX F2000 — 2048 Wh , 2400 W continuous , surge not published on the page we checked
- DJI Power 2000 — 2048 Wh , 3000 W continuous , surge not published on the page we checked
- EcoFlow DELTA 3 Max — 2048 Wh , 2400 W continuous , 4800 W surge published
- EcoFlow DELTA 3 Max Plus — 2048 Wh , 3000 W continuous , 6000 W surge published
- Pecron E2400LFP — 2048 Wh , 2400 W continuous , 4000 W surge published
- BLUETTI Elite 200 V2 — 2073.6 Wh , 2600 W continuous , surge not published on the page we checked
- Pecron E3600LFP — 3072 Wh , 3600 W continuous , 7000 W surge published
- EcoFlow DELTA Pro 3 — 4096 Wh , 4000 W continuous , 8000 W surge published
- Jackery Explorer 5000 Plus — 5040 Wh , 7200 W continuous , 14400 W surge published
Outlets, transfer, and what not to improvise
Plugging a station into a wall outlet with a homemade backfeed cord can energize house wiring and is a known hazard to line workers. Connecting a station to a panel, inlet, or transfer switch is work for a licensed electrician using listed equipment. This site does not provide wiring steps.
Some spec sheets list a UPS switchover time in milliseconds. That figure describes how the manufacturer characterizes the transfer. It is not a promise that every computer, network device, or other sensitive load will ride through an outage. Test the combination you care about before you rely on it.
Do not use these pages to decide whether a power station can run medical or life-support equipment. Follow the device manufacturer and a clinician’s instructions.