Use case · medical disclaimer · specs checked November 21, 2026

Power station sizing notes for CPAP (planning only)

Planning math for a low continuous AC or DC load such as a CPAP machine: watt-hours, inverter losses, and overnight runtime estimates. Not medical advice.

The math

Start from the appliance label: running watts (and startup watts if printed). Watt-hours on a station are nameplate capacity. Usable energy in our calculator is capacity × depth of discharge (default 90%). AC loads are divided by inverter efficiency (default 85%); USB / 12 V loads use DC efficiency (default 95%). Duty cycle is the fraction of time the load draws its running watts—critical for fridges and coolers.

Continuous watts must clear the simultaneous AC running load. Surge (when published) is only useful if you know the compressor’s startup draw. None of these defaults are manufacturer guarantees; change them in the calculator when you have better numbers.

Filter criteria: capacity ≥ 500 Wh and continuous AC ≥ 200 W when using an AC brick. Replace the example watts with your machine’s label in the calculator for an overnight estimate under the site’s defaults (90% DoD, 85% inverter / 95% DC efficiency).

Shortlist from this catalog

Station Summary Example runtime
Jackery Explorer 5000 Plus Jackery Explorer 5000 Plus: 5,040 Wh, LiFePO4, 7,200 W continuous AC, 14,400 W surge. · 134.5 lb Example AC brick at 60 W continuous (replace with your label): 64 h 16 min
EcoFlow DELTA Pro 3 EcoFlow DELTA Pro 3: 4,096 Wh, LFP (LiFePO4), 4,000 W continuous AC, 8,000 W surge. · 113.5 lb Example AC brick at 60 W continuous (replace with your label): 52 h 13 min
Pecron E3600LFP Pecron E3600LFP: 3,072 Wh, LiFePO4, 3,600 W continuous AC, 7,000 W surge. · 79.0 lb Example AC brick at 60 W continuous (replace with your label): 39 h 10 min
BLUETTI Elite 200 V2 BLUETTI Elite 200 V2: 2,073.6 Wh, LiFePO4, 2,600 W continuous AC. · 53.4 lb Example AC brick at 60 W continuous (replace with your label): 26 h 26 min
EcoFlow DELTA 2 Max EcoFlow DELTA 2 Max: 2,048 Wh, LFP, 2,400 W continuous AC, 4,800 W surge. · ≈ 50.7 lb Example AC brick at 60 W continuous (replace with your label): 26 h 7 min
Jackery HomePower 2000 Plus v2 Jackery HomePower 2000 Plus v2: 2,048 Wh, LFP, 2,400 W continuous AC. Example AC brick at 60 W continuous (replace with your label): 26 h 7 min
BLUETTI AC200L BLUETTI AC200L: 2,048 Wh, LiFePO4, 2,400 W continuous AC. · 62.4 lb Example AC brick at 60 W continuous (replace with your label): 26 h 7 min
Anker SOLIX C2000 Gen 2 Anker SOLIX C2000 Gen 2: 2,048 Wh, LFP, 2,400 W continuous AC, 4,000 W surge. · 41.7 lb Example AC brick at 60 W continuous (replace with your label): 26 h 7 min
Anker SOLIX F2000 Anker SOLIX F2000: 2,048 Wh, LFP (LiFePO4), 2,400 W continuous AC. · 67.2 lb Example AC brick at 60 W continuous (replace with your label): 26 h 7 min
DJI Power 2000 DJI Power 2000: 2,048 Wh, LFP (lithium ferrophosphate), 3,000 W continuous AC. · ≈ 48.5 lb Example AC brick at 60 W continuous (replace with your label): 26 h 7 min
EcoFlow DELTA 3 Max EcoFlow DELTA 3 Max: 2,048 Wh, LFP (LiFePO4), 2,400 W continuous AC, 4,800 W surge. · ≈ 44.8 lb Example AC brick at 60 W continuous (replace with your label): 26 h 7 min
EcoFlow DELTA 3 Max Plus EcoFlow DELTA 3 Max Plus: 2,048 Wh, LFP, 3,000 W continuous AC, 6,000 W surge. · ≈ 48.7 lb Example AC brick at 60 W continuous (replace with your label): 26 h 7 min
Pecron E2400LFP Pecron E2400LFP: 2,048 Wh, LiFePO4, 2,400 W continuous AC, 4,000 W surge. · 45.0 lb Example AC brick at 60 W continuous (replace with your label): 26 h 7 min
Jackery Explorer 2000 Plus Jackery Explorer 2000 Plus: 2,042.8 Wh, LiFePO₄, 3,000 W continuous AC, 6,000 W surge. · ≈ 61.5 lb Example AC brick at 60 W continuous (replace with your label): 26 h 3 min
Jackery Explorer 2000 v2 Jackery Explorer 2000 v2: 2,042 Wh, LiFePO4, 2,200 W continuous AC, 4,400 W surge. · 39.5 lb Example AC brick at 60 W continuous (replace with your label): 26 h 2 min
Pecron E1500LFP Pecron E1500LFP: 1,536 Wh, LiFePO4, 2,200 W continuous AC, 4,400 W surge. · 38.4 lb Example AC brick at 60 W continuous (replace with your label): 19 h 35 min
Goal Zero Yeti 1500 Goal Zero Yeti 1500: 1,505.28 Wh, LiFePO4, 2,000 W continuous AC, 3,600 W surge. · 52.8 lb Example AC brick at 60 W continuous (replace with your label): 19 h 12 min
BLUETTI AC180P BLUETTI AC180P: 1,440 Wh, LiFePO4 (Lithium Iron Phosphate), 1,800 W continuous AC, 2,700 W surge. · 35.3 lb Example AC brick at 60 W continuous (replace with your label): 18 h 22 min
Jackery Explorer 1000 Plus Jackery Explorer 1000 Plus: 1,264.64 Wh, LiFePO4, 2,000 W continuous AC, 4,000 W surge. · 32.0 lb Example AC brick at 60 W continuous (replace with your label): 16 h 7 min
BLUETTI AC180 BLUETTI AC180: 1,152 Wh, LiFePO4, 1,800 W continuous AC, 2,700 W surge. · 35.3 lb Example AC brick at 60 W continuous (replace with your label): 14 h 41 min
Jackery Explorer 1000 v2 Jackery Explorer 1000 v2: 1,070 Wh, LiFePO4, 1,500 W continuous AC, 3,000 W surge. · 23.8 lb Example AC brick at 60 W continuous (replace with your label): 13 h 39 min
Anker SOLIX C1000 Anker SOLIX C1000: 1,056 Wh, LiFePO4, 1,800 W continuous AC. · 28.4 lb Example AC brick at 60 W continuous (replace with your label): 13 h 28 min
EcoFlow DELTA 2 EcoFlow DELTA 2: 1,024 Wh, LFP, 1,800 W continuous AC, 2,700 W surge. · 27.0 lb Example AC brick at 60 W continuous (replace with your label): 13 h 3 min
EcoFlow DELTA 3 Plus EcoFlow DELTA 3 Plus: 1,024 Wh, LFP (LiFePO4), 1,800 W continuous AC, 3,600 W surge. · 27.6 lb Example AC brick at 60 W continuous (replace with your label): 13 h 3 min
BLUETTI Elite 100 V2 BLUETTI Elite 100 V2: 1,024 Wh, LiFePO4, 1,800 W continuous AC. · 25.0 lb Example AC brick at 60 W continuous (replace with your label): 13 h 3 min
Anker SOLIX C1000 Gen 2 Anker SOLIX C1000 Gen 2: 1,024 Wh, 2,000 W continuous AC, 3,000 W surge. Example AC brick at 60 W continuous (replace with your label): 13 h 3 min
DJI Power 1000 DJI Power 1000: 1,024 Wh, LFP (lithium ferrophosphate), 2,200 W continuous AC, 4,400 W surge. · ≈ 28.7 lb Example AC brick at 60 W continuous (replace with your label): 13 h 3 min
Pecron E1000LFP Pecron E1000LFP: 1,024 Wh, LiFePO4, 1,800 W continuous AC, 3,000 W surge. · 29.0 lb Example AC brick at 60 W continuous (replace with your label): 13 h 3 min
Goal Zero Yeti 1000 Goal Zero Yeti 1000: 998.4 Wh, LiFePO4, 2,000 W continuous AC, 3,600 W surge. · 35.3 lb Example AC brick at 60 W continuous (replace with your label): 12 h 44 min
BLUETTI AC70P BLUETTI AC70P: 864 Wh, LiFePO4, 1,000 W continuous AC, 2,000 W surge. · 22.5 lb Example AC brick at 60 W continuous (replace with your label): 11 h 1 min
BLUETTI AC70 BLUETTI AC70: 768 Wh, LiFePO4, 1,000 W continuous AC, 1,500 W surge. · 22.5 lb Example AC brick at 60 W continuous (replace with your label): 9 h 48 min
Anker SOLIX C800 Plus Anker SOLIX C800 Plus: 768 Wh, LiFePO4, 1,200 W continuous AC. · ≈ 24.0 lb Example AC brick at 60 W continuous (replace with your label): 9 h 48 min
Goal Zero Yeti 700 Goal Zero Yeti 700: 677.37 Wh, LiFePO4 (Lithium Iron Phosphate), 600 W continuous AC, 1,000 W surge. · 20.3 lb Example AC brick at 60 W continuous (replace with your label): 8 h 38 min
EcoFlow RIVER 3 Max EcoFlow RIVER 3 Max: 572 Wh, LiFePO4, 600 W continuous AC, 1,200 W surge. · ≈ 18.5 lb Example AC brick at 60 W continuous (replace with your label): 7 h 18 min

Compare shortlisted models in the interactive tool ( prefill top 4 ).

Try the calculator

Prefills the first shortlisted station when available. Adjust loads to match your labels.

Station

Nameplate 5040 Wh. Continuous 7200 W. Surge 14400 W. Spec sheet.

Assumptions

Depth of discharge is the share of nameplate watt-hours treated as usable. The default is 90% because spec sheets usually publish nameplate capacity, not the watt-hours the battery management system delivers on every cycle. Change it if you want a more conservative or more optimistic plan.

Loads

Wattages are editable starting points. Medical and life-support devices are not in this list. Use the label on your own gear.

Laptop (USB-C)
Wi-Fi router
LED lantern
Phone charger

Sources and limits

  • Station specs: linked manufacturer pages on each station sheet (checked November 21, 2026).
  • Runtime math: methodology and the calculator defaults above.
  • This page does not claim a model is safe for your appliance, trip, or medical device.