Anker · Solar panel

Anker SOLIX PS400 Bifacial 400W

Anker SOLIX PS400 Bifacial 400W: 400 W, 57.6 V Voc, 8.75 A Isc. Station compatibility & charge estimates checked November 21, 2026.

  • Rated power 400 W
  • Voc (STC) 57.6 V
  • Isc (STC) 8.75 A
  • Connector MC4

Check price

Manufacturer specs

Spec Published figure Source
Price Current manufacturer-direct or listed US price with source link and check date. $799.99 ankersolix.com
Rated power 400 W ankersolix.com
Open-circuit voltage (Voc) Open-circuit voltage (Voc) is measured at 25 °C (77 °F) with no load. Solar panel Voc rises in cold weather (~0.3%/°C below 25 °C), so we apply a +15% cold-weather safety margin before declaring a string safe for a station's max input voltage. 57.6 V (+15% cold margin: 66.2 V) ankersolix.com
Short-circuit current (Isc) Short-circuit current (Isc) is the panel's maximum current output. Unlike over-voltage (which can damage an MPPT controller), exceeding a station's max input amps generally clips or caps charging current at the station's limit. 8.75 A ankersolix.com
Operating voltage (Vmp) 48 V ankersolix.com
Operating current (Imp) 8.33 A ankersolix.com
Connector MC4 — MC4 output with included XT60i solar charging cable. ankersolix.com
Weight How heavy the station is to lift and carry. 21.9 lb ankersolix.com
Folded size 22.3 × 38.7 × 3.2 in ankersolix.com

Compatible power stations

Checks Voc with +15% cold margin Open-circuit voltage (Voc) is measured at 25 °C (77 °F) with no load. Solar panel Voc rises in cold weather (~0.3%/°C below 25 °C), so we apply a +15% cold-weather safety margin before declaring a string safe for a station's max input voltage. , array limits Wiring panels in series adds Voc (must stay under the station's max voltage with cold-weather margin). Wiring in parallel adds current (Isc). Counts are shown only when both station limits and panel Voc/Isc are published. , connector adapters, and 1-panel charge time Charge-time estimates apply a 75% real-world solar derating factor (midpoint of a typical 70–80% range) to account for sun angle, temperature, haze, and conversion losses. Actual harvest varies with weather and shading. .

Power station Status Series / parallel Connector & notes Est. 1-panel charge
Anker SOLIX F3800 Plus (3,840 Wh) Compatible Up to 2S × 1P per port (4 max across 2 ports)
Included adapter (MC4 → XT60)
Voc (57.6 V, cold 66.24 V) and Isc (8.75 A) fit Dual MPPT solar inputs (11–165 V, 17 A).
~12.8 hrs (est.)
BLUETTI AC200L (2,048 Wh) Compatible (adapter) Up to 2S × 1P per port (2 max)
Adapter needed (MC4 → Aviation)
Voc (57.6 V, cold 66.24 V) and Isc (8.75 A) fit 2-pin aviation PV input (12–145 V, 15 A).
~6.8 hrs (est.)
Pecron E2400LFP (2,048 Wh) Compatible (adapter) Up to 1S × 1P per port (1 max)
Adapter needed (MC4 → GX16MF)
Voc (57.6 V, cold 66.24 V) and Isc (8.75 A) fit GX16MF solar port (32–95 V, 15 A).
~6.8 hrs (est.)
Pecron E3600LFP (3,072 Wh) Compatible Up to 2S × 2P per port (8 max across 2 ports)
Included adapter (MC4 → XT60)
Voc (57.6 V, cold 66.24 V) and Isc (8.75 A) fit Dual XT60-M inputs (32–150 V, 20 A).
~10.2 hrs (est.)
Pecron E3800LFP (3,840 Wh) Compatible Up to 2S × 2P per port (8 max across 2 ports)
Included adapter (MC4 → XT60)
Voc (57.6 V, cold 66.24 V) and Isc (8.75 A) fit Dual XT60-M solar inputs (32–150 V, 20 A).
~12.8 hrs (est.)
EcoFlow DELTA Pro 3 (4,096 Wh) Compatible Up to 2S × 1P per port (2 max)
Included adapter (MC4 → XT60i)
Voc (57.6 V, cold 66.24 V) and Isc (8.75 A) fit High-PV port (30–150 V, 15 A).
~13.7 hrs (est.)
Jackery Explorer 5000 Plus (5,040 Wh) Compatible Up to 6S × 1P per port (6 max)
Direct MC4 fit
Requires at least 3 panels in series to reach 135 V minimum.
~16.8 hrs (est.)
Anker SOLIX C800 Plus (768 Wh) Caution (Cold Voc) Up to 1S × 1P per port (1 max)
Included adapter (MC4 → XT60)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V. Input capped at 300 W per port (panel 400 W).
~3.4 hrs (est.)
Anker SOLIX C1000 (1,056 Wh) Caution (Cold Voc) Up to 1S × 1P per port (1 max)
Included adapter (MC4 → XT60)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~3.5 hrs (est.)
Anker SOLIX S2000 (2,010 Wh) Caution (Cold Voc) Up to 1S × 1P per port (1 max)
Included adapter (MC4 → XT60i)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~6.7 hrs (est.)
Anker SOLIX F2000 (2,048 Wh) Caution (Cold Voc) Up to 1S × 2P per port (2 max)
Included adapter (MC4 → XT60)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~6.8 hrs (est.)
BLUETTI AC70 (768 Wh) Caution (Cold Voc) Up to 1S × 1P per port (1 max)
Included adapter (MC4 → XT60)
25 °C Voc (57.6 V) fits ≤58 V, but +15% cold margin (66.24 V) exceeds 58 V.
~2.6 hrs (est.)
BLUETTI AC70P (864 Wh) Caution (Cold Voc) Up to 1S × 1P per port (1 max)
Included adapter (MC4 → XT60)
25 °C Voc (57.6 V) fits ≤58 V, but +15% cold margin (66.24 V) exceeds 58 V.
~2.9 hrs (est.)
Pecron F1000LFP (960 Wh) Caution (Cold Voc) Up to 1S × 1P per port (1 max)
Included adapter (MC4 → XT60)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~3.2 hrs (est.)
EcoFlow DELTA 2 (1,024 Wh) Caution (Cold Voc) Up to 1S × 1P per port (1 max)
Included adapter (MC4 → XT60)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~3.4 hrs (est.)
EcoFlow DELTA 3 Plus (1,024 Wh) Caution (Cold Voc) Up to 1S × 1P per port (2 max across 2 ports)
Included adapter (MC4 → XT60)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~3.4 hrs (est.)
BLUETTI Elite 100 V2 (1,024 Wh) Caution (Cold Voc) Up to 1S × 2P per port (2 max)
Included adapter (MC4 → XT60)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~3.4 hrs (est.)
Pecron E1000LFP (1,024 Wh) Caution (Cold Voc) Up to 1S × 2P per port (2 max)
Included adapter (MC4 → XT60)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~3.4 hrs (est.)
Jackery Explorer 1000 v2 (1,070 Wh) Caution (Cold Voc) Up to 1S × 1P per port (2 max across 2 ports)
Adapter needed (MC4 → DC8020)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V. Input capped at 200 W per port (panel 400 W).
~7.1 hrs (est.)
BLUETTI AC180 (1,152 Wh) Caution (Cold Voc) Up to 1S × 1P per port (1 max)
Adapter needed (MC4 → DC7909)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~3.8 hrs (est.)
Jackery Explorer 1000 Plus (1,264.64 Wh) Caution (Cold Voc) Up to 1S × 1P per port (2 max across 2 ports)
Adapter needed (MC4 → DC8020)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~4.2 hrs (est.)
BLUETTI AC180P (1,440 Wh) Caution (Cold Voc) Up to 1S × 1P per port (1 max)
Adapter needed (MC4 → DC7909)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~4.8 hrs (est.)
Pecron E1500LFP (1,536 Wh) Caution (Cold Voc) Up to 1S × 2P per port (2 max)
Included adapter (MC4 → XT60)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~5.1 hrs (est.)
Jackery Explorer 2000 v2 (2,042 Wh) Caution (Cold Voc) Up to 1S × 1P per port (2 max across 2 ports)
Adapter needed (MC4 → DC8020)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V. Input capped at 200 W per port (panel 400 W).
~13.6 hrs (est.)
Jackery Explorer 2000 Plus (2,042.8 Wh) Caution (Cold Voc) Up to 1S × 1P per port (2 max across 2 ports)
Adapter needed (MC4 → DC8020)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~6.8 hrs (est.)
EcoFlow DELTA 2 Max (2,048 Wh) Caution (Cold Voc) Up to 1S × 1P per port (2 max across 2 ports)
Included adapter (MC4 → XT60)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~6.8 hrs (est.)
EcoFlow DELTA 3 Max (2,048 Wh) Caution (Cold Voc) Up to 1S × 1P per port (1 max)
Included adapter (MC4 → XT60)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~6.8 hrs (est.)
EcoFlow DELTA 3 Max Plus (2,048 Wh) Caution (Cold Voc) Up to 1S × 1P per port (2 max across 2 ports)
Included adapter (MC4 → XT60)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~6.8 hrs (est.)
BLUETTI Elite 200 V2 (2,073.6 Wh) Caution (Cold Voc) Up to 1S × 2P per port (2 max)
Included adapter (MC4 → XT60)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~6.9 hrs (est.)
BLUETTI Elite 300 (3,014.4 Wh) Caution (Cold Voc) Up to 1S × 2P per port (2 max)
Included adapter (MC4 → XT60)
25 °C Voc (57.6 V) fits ≤60 V, but +15% cold margin (66.24 V) exceeds 60 V.
~10 hrs (est.)
Anker 521 PowerHouse (256 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Anker 535 PowerHouse (512 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Anker SOLIX C1000 Gen 2 (1,024 Wh) Check with manufacturer Check with manufacturer
Included adapter (MC4 → XT60)
Published limits incomplete to verify full array (Cold-weather Voc (~66.24 V) exceeds 60 V max.)
—
Anker 757 PowerHouse (1,229 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Anker SOLIX C2000 Gen 2 (2,048 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Anker SOLIX F2600 (2,560 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Anker SOLIX F3000 (3,072 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Anker SOLIX F3800 (3,840 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
BLUETTI AC2A (204.8 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
EcoFlow RIVER 3 (245 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
EcoFlow RIVER 2 (256 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Jackery Explorer 240 v2 (256 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
BLUETTI EB3A (268.8 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Pecron E300LFP (288 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Jackery Explorer 300 (293 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Goal Zero Yeti 300 (296.96 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
BLUETTI AC60 (403.2 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
BLUETTI AC50B (448 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Goal Zero Yeti 500X (497 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Goal Zero Yeti 500 (499.2 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
EcoFlow RIVER 2 Max (512 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Jackery Explorer 500 (518 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Pecron E500LFP (576 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Jackery Explorer 600 v2 (640 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
EcoFlow RIVER 2 Pro (768 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Goal Zero Yeti 1000X (997 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
EcoFlow DELTA 3 Classic (1,024 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
EcoFlow DELTA 3 (1,024 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Jackery HomePower 1000 Plus v2 (1,024 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Jackery Explorer 1500 v2 (1,536 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Jackery Explorer 1500 Ultra (1,536 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
BLUETTI AC240 (1,536 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Jackery HomePower 2000 Plus v2 (2,048 Wh) Check with manufacturer Check with manufacturer
Adapter needed (MC4 → DC8020)
Published limits incomplete to verify full array (Cold-weather Voc (~66.24 V) exceeds 60 V max.)
—
BLUETTI AC200MAX (2,048 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
BLUETTI Apex 300 (2,764.8 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Goal Zero Yeti 3000X (3,032 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
EcoFlow DELTA 3 Ultra (3,072 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Jackery HomePower 3000 (3,072 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Pecron F3000LFP (3,072 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Jackery HomePower 3600 Plus (3,584 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
EcoFlow DELTA Pro (3,600 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Pecron F5000LFP (5,120 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Goal Zero Yeti 6000X (6,071 Wh) Check with manufacturer Check with manufacturer
Station solar voltage/current limits not published in full
—
Anker SOLIX C300 (288 Wh) Incompatible (Over-voltage) 0 panels (over-voltage)
Included adapter (MC4 → XT60)
Panel Voc (57.6 V) exceeds XT60 solar input max input (28 V) — risk of MPPT damage.
—
EcoFlow RIVER 3 Plus (286 Wh) Incompatible (Over-voltage) 0 panels (over-voltage)
Included adapter (MC4 → XT60)
Panel Voc (57.6 V) exceeds XT60 solar input max input (55 V) — risk of MPPT damage.
—
Jackery Explorer 300 Plus (288 Wh) Incompatible (Over-voltage) 0 panels (over-voltage)
Adapter needed (MC4 → DC8020)
Panel Voc (57.6 V) exceeds DC8020 input max input (27 V) — risk of MPPT damage.
—
BLUETTI Elite 30 V2 (288 Wh) Incompatible (Over-voltage) 0 panels (over-voltage)
Included adapter (MC4 → XT60)
Panel Voc (57.6 V) exceeds XT60 solar input max input (28 V) — risk of MPPT damage.
—
DJI Power 500 (512 Wh) Incompatible (Over-voltage) 0 panels (over-voltage)
Requires DJI Power Solar Panel Adapter Module (MPPT)
Panel Voc (57.6 V) exceeds Solar via DJI MPPT adapter max input (30 V) — risk of MPPT damage.
—
EcoFlow RIVER 3 Max (572 Wh) Incompatible (Over-voltage) 0 panels (over-voltage)
Included adapter (MC4 → XT60)
Panel Voc (57.6 V) exceeds XT60 solar input max input (55 V) — risk of MPPT damage.
—
Goal Zero Yeti 700 (677.37 Wh) Incompatible (Over-voltage) 0 panels (over-voltage)
Adapter needed (MC4 → DC7909)
Panel Voc (57.6 V) exceeds 8 mm (DC7909) solar input max input (28 V) — risk of MPPT damage.
—
Goal Zero Yeti 1000 (998.4 Wh) Incompatible (Over-voltage) 0 panels (over-voltage)
Adapter needed (MC4 → HPP)
Panel Voc (57.6 V) exceeds HPP solar port max input (50 V) — risk of MPPT damage.
—
DJI Power 1000 (1,024 Wh) Incompatible (Over-voltage) 0 panels (over-voltage)
Requires DJI Power Solar Panel Adapter Module (MPPT)
Panel Voc (57.6 V) exceeds SDC via MPPT adapter module (×2) max input (30 V) — risk of MPPT damage.
—
DJI Power 1000 V2 (1,024 Wh) Incompatible (Over-voltage) 0 panels (over-voltage)
Requires DJI Power Solar Panel Adapter Module (MPPT)
Panel Voc (57.6 V) exceeds SDC via MPPT adapter module max input (30 V) — risk of MPPT damage.
—
Goal Zero Yeti 1500 (1,505.28 Wh) Incompatible (Over-voltage) 0 panels (over-voltage)
Adapter needed (MC4 → HPP)
Panel Voc (57.6 V) exceeds HPP solar port max input (50 V) — risk of MPPT damage.
—
DJI Power 2000 (2,048 Wh) Incompatible (Over-voltage) 0 panels (over-voltage)
Requires DJI Power Solar Panel Adapter Module (MPPT)
Panel Voc (57.6 V) exceeds SDC via MPPT adapter module (×2) max input (30 V) — risk of MPPT damage.
—

Notes from the source pages

  • 48 V operating / 57.6 V Voc output; check cold-weather Voc margin against 60 V-max ports and never series-connect on 60 V inputs.

Sources

Checked November 21, 2026. Spot an error? Report an error .