Jackery · Solar panel
Jackery SolarSaga 100 Prime
Jackery SolarSaga 100 Prime: 100 W, 22.7 V Voc, 5.53 A Isc. Station compatibility & charge estimates checked November 21, 2026.
- Rated power 100 W
- Voc (STC) 22.7 V
- Isc (STC) 5.53 A
- Connector Anderson
Check price
Manufacturer specs
| Spec | Published figure | Source |
|---|---|---|
| Price Current manufacturer-direct or listed US price with source link and check date. | $249.00 | jackery.com |
| Rated power | 100 W | jackery.com |
| Open-circuit voltage (Voc) Open-circuit voltage (Voc) is measured at 25 °C (77 °F) with no load. Solar panel Voc rises in cold weather (~0.3%/°C below 25 °C), so we apply a +15% cold-weather safety margin before declaring a string safe for a station's max input voltage. | 22.7 V (+15% cold margin: 26.1 V) | jackery.com |
| Short-circuit current (Isc) Short-circuit current (Isc) is the panel's maximum current output. Unlike over-voltage (which can damage an MPPT controller), exceeding a station's max input amps generally clips or caps charging current at the station's limit. | 5.53 A | jackery.com |
| Connector | Anderson — Jackery Anderson connector with included Anderson-to-DC8020 adapter (DC8020-to-DC7909 required for older 8 mm stations). | jackery.com |
| Weight How heavy the station is to lift and carry. | 13.23 lb (6 kg) | jackery.com |
| Dimensions | 38.8 × 21.7 × 1.1 in | jackery.com |
Compatible power stations
Checks Voc with +15% cold margin Open-circuit voltage (Voc) is measured at 25 °C (77 °F) with no load. Solar panel Voc rises in cold weather (~0.3%/°C below 25 °C), so we apply a +15% cold-weather safety margin before declaring a string safe for a station's max input voltage. , array limits Wiring panels in series adds Voc (must stay under the station's max voltage with cold-weather margin). Wiring in parallel adds current (Isc). Counts are shown only when both station limits and panel Voc/Isc are published. , connector adapters, and 1-panel charge time Charge-time estimates apply a 75% real-world solar derating factor (midpoint of a typical 70–80% range) to account for sun angle, temperature, haze, and conversion losses. Actual harvest varies with weather and shading. .
| Power station | Status | Series / parallel | Connector & notes | Est. 1-panel charge |
|---|---|---|---|---|
| Jackery Explorer 300 Plus | Compatible | Up to 1S × 1P per port (1 max) | Included adapter (Anderson → DC8020) | ~4.2 hrs (est.) |
| Jackery Explorer 1000 v2 | Compatible | Up to 2S × 1P per port (4 max across 2 ports) | Included adapter (Anderson → DC8020) | ~14.3 hrs (est.) |
| Jackery Explorer 1000 Plus | Compatible | Up to 2S × 1P per port (4 max across 2 ports) | Included adapter (Anderson → DC8020) | ~16.9 hrs (est.) |
| Jackery Explorer 2000 v2 | Compatible | Up to 2S × 2P per port (8 max across 2 ports) | Included adapter (Anderson → DC8020) | ~27.2 hrs (est.) |
| Jackery Explorer 2000 Plus | Compatible | Up to 2S × 2P per port (8 max across 2 ports) | Included adapter (Anderson → DC8020) | ~27.2 hrs (est.) |
| Jackery Explorer 5000 Plus | Compatible | Up to 2S × 1P per port (4 max across 2 ports) | Included adapter (Anderson → DC8020) | ~67.2 hrs (est.) |
| EcoFlow RIVER 3 Plus | Compatible (adapter) | Up to 2S × 2P per port (4 max) | Adapter needed (Anderson → XT60) | ~3.8 hrs (est.) |
| BLUETTI Elite 30 V2 | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (Anderson → XT60) | ~3.8 hrs (est.) |
| Anker SOLIX C300 | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (Anderson → XT60) | ~3.8 hrs (est.) |
| EcoFlow RIVER 3 Max | Compatible (adapter) | Up to 2S × 2P per port (4 max) | Adapter needed (Anderson → XT60) | ~7.6 hrs (est.) |
| Goal Zero Yeti 700 | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (Anderson → DC7909) | ~9 hrs (est.) |
| BLUETTI AC70 | Compatible (adapter) | Up to 2S × 1P per port (2 max) | Adapter needed (Anderson → XT60) | ~10.2 hrs (est.) |
| Anker SOLIX C800 Plus | Compatible (adapter) | Up to 2S × 1P per port (2 max) | Adapter needed (Anderson → XT60) | ~10.2 hrs (est.) |
| BLUETTI AC70P | Compatible (adapter) | Up to 2S × 1P per port (2 max) | Adapter needed (Anderson → XT60) | ~11.5 hrs (est.) |
| Pecron F1000LFP | Compatible (adapter) | Up to 2S × 2P per port (4 max) | Adapter needed (Anderson → XT60) | ~12.8 hrs (est.) |
| Goal Zero Yeti 1000 | Compatible (adapter) | Up to 1S × 9P per port (9 max) | Adapter needed (Anderson → HPP) | ~13.3 hrs (est.) |
| EcoFlow DELTA 2 | Compatible (adapter) | Up to 2S × 2P per port (4 max) | Adapter needed (Anderson → XT60) | ~13.7 hrs (est.) |
| EcoFlow DELTA 3 Plus | Compatible (adapter) | Up to 2S × 2P per port (8 max across 2 ports) | Adapter needed (Anderson → XT60) | ~13.7 hrs (est.) |
| BLUETTI Elite 100 V2 | Compatible (adapter) | Up to 2S × 3P per port (6 max) | Adapter needed (Anderson → XT60) | ~13.7 hrs (est.) |
| Pecron E1000LFP | Compatible (adapter) | Up to 2S × 3P per port (6 max) | Adapter needed (Anderson → XT60) | ~13.7 hrs (est.) |
| Anker SOLIX C1000 | Compatible (adapter) | Up to 2S × 2P per port (4 max) | Adapter needed (Anderson → XT60) | ~14.1 hrs (est.) |
| BLUETTI AC180 | Compatible (adapter) | Up to 2S × 1P per port (2 max) | Adapter needed (Anderson → DC7909) | ~15.4 hrs (est.) |
| BLUETTI AC180P | Compatible (adapter) | Up to 2S × 1P per port (2 max) | Adapter needed (Anderson → DC7909) | ~19.2 hrs (est.) |
| Goal Zero Yeti 1500 | Compatible (adapter) | Up to 1S × 9P per port (9 max) | Adapter needed (Anderson → HPP) | ~20.1 hrs (est.) |
| Pecron E1500LFP | Compatible (adapter) | Up to 2S × 3P per port (6 max) | Adapter needed (Anderson → XT60) | ~20.5 hrs (est.) |
| Anker SOLIX S2000 | Compatible (adapter) | Up to 2S × 2P per port (4 max) | Adapter needed (Anderson → XT60i) | ~26.8 hrs (est.) |
| EcoFlow DELTA 2 Max | Compatible (adapter) | Up to 2S × 2P per port (8 max across 2 ports) | Adapter needed (Anderson → XT60) | ~27.3 hrs (est.) |
| BLUETTI AC200L | Compatible (adapter) | Up to 5S × 2P per port (10 max) | Adapter needed (Anderson → Aviation) | ~27.3 hrs (est.) |
| Anker SOLIX F2000 | Compatible (adapter) | Up to 2S × 3P per port (6 max) | Adapter needed (Anderson → XT60) | ~27.3 hrs (est.) |
| EcoFlow DELTA 3 Max | Compatible (adapter) | Up to 2S × 2P per port (4 max) | Adapter needed (Anderson → XT60) | ~27.3 hrs (est.) |
| EcoFlow DELTA 3 Max Plus | Compatible (adapter) | Up to 2S × 2P per port (8 max across 2 ports) | Adapter needed (Anderson → XT60) | ~27.3 hrs (est.) |
| Pecron E2400LFP | Compatible (adapter) | Up to 3S × 2P per port (6 max) | Adapter needed (Anderson → GX16MF) | ~27.3 hrs (est.) |
| BLUETTI Elite 200 V2 | Compatible (adapter) | Up to 2S × 3P per port (6 max) | Adapter needed (Anderson → XT60) | ~27.6 hrs (est.) |
| BLUETTI Elite 300 | Compatible (adapter) | Up to 2S × 3P per port (6 max) | Adapter needed (Anderson → XT60) | ~40.2 hrs (est.) |
| Pecron E3600LFP | Compatible (adapter) | Up to 5S × 3P per port (30 max across 2 ports) | Adapter needed (Anderson → XT60) | ~41 hrs (est.) |
| Anker SOLIX F3800 Plus | Compatible (adapter) | Up to 6S × 3P per port (36 max across 2 ports) | Adapter needed (Anderson → XT60) | ~51.2 hrs (est.) |
| Pecron E3800LFP | Compatible (adapter) | Up to 5S × 3P per port (30 max across 2 ports) | Adapter needed (Anderson → XT60) | ~51.2 hrs (est.) |
| EcoFlow DELTA Pro 3 | Compatible (adapter) | Up to 5S × 2P per port (10 max) | Adapter needed (Anderson → XT60i) | ~54.6 hrs (est.) |
| Jackery Explorer 240 v2 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery Explorer 300 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery Explorer 500 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery Explorer 600 v2 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery HomePower 1000 Plus v2 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery Explorer 1500 v2 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery Explorer 1500 Ultra | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery HomePower 2000 Plus v2 | Check with manufacturer | Check with manufacturer | Included adapter (Anderson → DC8020) | — |
| Jackery HomePower 3000 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery HomePower 3600 Plus | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| BLUETTI AC2A | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| EcoFlow RIVER 3 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| EcoFlow RIVER 2 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Anker 521 PowerHouse | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| BLUETTI EB3A | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Pecron E300LFP | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Goal Zero Yeti 300 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| BLUETTI AC60 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| BLUETTI AC50B | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Goal Zero Yeti 500X | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Goal Zero Yeti 500 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| EcoFlow RIVER 2 Max | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Anker 535 PowerHouse | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| DJI Power 500 | Check with manufacturer | Check with manufacturer | Requires DJI Power Solar Panel Adapter Module (MPPT) + Anderson→XT60 cable | — |
| Pecron E500LFP | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| EcoFlow RIVER 2 Pro | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Goal Zero Yeti 1000X | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Anker SOLIX C1000 Gen 2 | Check with manufacturer | Check with manufacturer | Adapter needed (Anderson → XT60) | — |
| DJI Power 1000 | Check with manufacturer | Check with manufacturer | Requires DJI Power Solar Panel Adapter Module (MPPT) + Anderson→XT60 cable | — |
| DJI Power 1000 V2 | Check with manufacturer | Check with manufacturer | Requires DJI Power Solar Panel Adapter Module (MPPT) + Anderson→XT60 cable | — |
| EcoFlow DELTA 3 Classic | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| EcoFlow DELTA 3 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Anker 757 PowerHouse | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| BLUETTI AC240 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Anker SOLIX C2000 Gen 2 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| DJI Power 2000 | Check with manufacturer | Check with manufacturer | Requires DJI Power Solar Panel Adapter Module (MPPT) + Anderson→XT60 cable | — |
| BLUETTI AC200MAX | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Anker SOLIX F2600 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| BLUETTI Apex 300 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Goal Zero Yeti 3000X | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| EcoFlow DELTA 3 Ultra | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Anker SOLIX F3000 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Pecron F3000LFP | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| EcoFlow DELTA Pro | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Anker SOLIX F3800 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Pecron F5000LFP | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Goal Zero Yeti 6000X | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
Notes from the source pages
- Non-foldable rigid bifacial panel (JS-100E); STC Voc 22.7 V / Isc 5.53 A (BNPI 23.0 V / 5.86 A).