Jackery · Solar panel
Jackery SolarSaga 500 X
Jackery SolarSaga 500 X: 500 W, 49.2 V Voc, 12.92 A Isc. Station compatibility & charge estimates checked November 21, 2026.
- Rated power 500 W
- Voc (STC) 49.2 V
- Isc (STC) 12.92 A
- Connector DC8020
Check price
Manufacturer specs
| Spec | Published figure | Source |
|---|---|---|
| Price Current manufacturer-direct or listed US price with source link and check date. | $999.00 | jackery.com |
| Rated power | 500 W | jackery.com |
| Open-circuit voltage (Voc) Open-circuit voltage (Voc) is measured at 25 °C (77 °F) with no load. Solar panel Voc rises in cold weather (~0.3%/°C below 25 °C), so we apply a +15% cold-weather safety margin before declaring a string safe for a station's max input voltage. | 49.2 V (+15% cold margin: 56.6 V) | jackery.com |
| Short-circuit current (Isc) Short-circuit current (Isc) is the panel's maximum current output. Unlike over-voltage (which can damage an MPPT controller), exceeding a station's max input amps generally clips or caps charging current at the station's limit. | 12.92 A | jackery.com |
| Connector | DC8020 — DC8020 parallel combiner output (DC8020-to-DC7909 adapter sold separately if needed). | jackery.com |
| Weight How heavy the station is to lift and carry. | 26.4 lb (12 kg) | jackery.com |
| Folded size | 996 × 526 × 97 mm (6-fold kit) | jackery.com |
Compatible power stations
Checks Voc with +15% cold margin Open-circuit voltage (Voc) is measured at 25 °C (77 °F) with no load. Solar panel Voc rises in cold weather (~0.3%/°C below 25 °C), so we apply a +15% cold-weather safety margin before declaring a string safe for a station's max input voltage. , array limits Wiring panels in series adds Voc (must stay under the station's max voltage with cold-weather margin). Wiring in parallel adds current (Isc). Counts are shown only when both station limits and panel Voc/Isc are published. , connector adapters, and 1-panel charge time Charge-time estimates apply a 75% real-world solar derating factor (midpoint of a typical 70–80% range) to account for sun angle, temperature, haze, and conversion losses. Actual harvest varies with weather and shading. .
| Power station | Status | Series / parallel | Connector & notes | Est. 1-panel charge |
|---|---|---|---|---|
| Jackery Explorer 1000 v2 | Compatible | Up to 1S × 1P per port (2 max across 2 ports) | Direct DC8020 fit | ~7.1 hrs (est.) |
| Jackery Explorer 1000 Plus | Compatible | Up to 1S × 1P per port (2 max across 2 ports) | Direct DC8020 fit | ~4.2 hrs (est.) |
| Jackery Explorer 2000 v2 | Compatible | Up to 1S × 1P per port (2 max across 2 ports) | Direct DC8020 fit | ~13.6 hrs (est.) |
| Jackery Explorer 2000 Plus | Compatible | Up to 1S × 1P per port (2 max across 2 ports) | Direct DC8020 fit | ~5.9 hrs (est.) |
| Jackery Explorer 5000 Plus | Compatible | Up to 1S × 1P per port (2 max across 2 ports) | Direct DC8020 fit | ~16.5 hrs (est.) |
| BLUETTI AC70 | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60) | ~2.6 hrs (est.) |
| Anker SOLIX C800 Plus | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60) | ~3.4 hrs (est.) |
| BLUETTI AC70P | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60) | ~3 hrs (est.) |
| Pecron F1000LFP | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60) | ~2.6 hrs (est.) |
| EcoFlow DELTA 2 | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60) | ~2.7 hrs (est.) |
| EcoFlow DELTA 3 Plus | Compatible (adapter) | Up to 1S × 1P per port (2 max across 2 ports) | Adapter needed (DC8020 → XT60) | ~2.7 hrs (est.) |
| BLUETTI Elite 100 V2 | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60) | ~2.7 hrs (est.) |
| Pecron E1000LFP | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60) | ~2.7 hrs (est.) |
| Anker SOLIX C1000 | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60) | ~2.8 hrs (est.) |
| BLUETTI AC180 | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → DC7909) | ~4 hrs (est.) |
| BLUETTI AC180P | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → DC7909) | ~5 hrs (est.) |
| Pecron E1500LFP | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60) | ~4.1 hrs (est.) |
| Anker SOLIX S2000 | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60i) | ~6.7 hrs (est.) |
| EcoFlow DELTA 2 Max | Compatible (adapter) | Up to 1S × 1P per port (2 max across 2 ports) | Adapter needed (DC8020 → XT60) | ~5.5 hrs (est.) |
| BLUETTI AC200L | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → Aviation) | ~5.5 hrs (est.) |
| Anker SOLIX F2000 | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60) | ~5.5 hrs (est.) |
| EcoFlow DELTA 3 Max | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60) | ~5.5 hrs (est.) |
| EcoFlow DELTA 3 Max Plus | Compatible (adapter) | Up to 1S × 1P per port (2 max across 2 ports) | Adapter needed (DC8020 → XT60) | ~5.5 hrs (est.) |
| Pecron E2400LFP | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → GX16MF) | ~5.5 hrs (est.) |
| BLUETTI Elite 200 V2 | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60) | ~5.5 hrs (est.) |
| BLUETTI Elite 300 | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60) | ~8 hrs (est.) |
| Pecron E3600LFP | Compatible (adapter) | Up to 1S × 1P per port (2 max across 2 ports) | Adapter needed (DC8020 → XT60) | ~8.2 hrs (est.) |
| Anker SOLIX F3800 Plus | Compatible (adapter) | Up to 1S × 1P per port (2 max across 2 ports) | Adapter needed (DC8020 → XT60) | ~10.2 hrs (est.) |
| Pecron E3800LFP | Compatible (adapter) | Up to 1S × 1P per port (2 max across 2 ports) | Adapter needed (DC8020 → XT60) | ~10.2 hrs (est.) |
| EcoFlow DELTA Pro 3 | Compatible (adapter) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60i) | ~10.9 hrs (est.) |
| EcoFlow RIVER 3 Plus | Caution (Cold Voc) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60) | ~1.7 hrs (est.) |
| EcoFlow RIVER 3 Max | Caution (Cold Voc) | Up to 1S × 1P per port (1 max) | Adapter needed (DC8020 → XT60) | ~3.5 hrs (est.) |
| Goal Zero Yeti 1000 | Caution (Cold Voc) | Up to 1S × 3P per port (3 max) | Adapter needed (DC8020 → HPP) | ~2.7 hrs (est.) |
| Goal Zero Yeti 1500 | Caution (Cold Voc) | Up to 1S × 3P per port (3 max) | Adapter needed (DC8020 → HPP) | ~4 hrs (est.) |
| Jackery Explorer 240 v2 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery Explorer 300 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery Explorer 500 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery Explorer 600 v2 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery HomePower 1000 Plus v2 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery Explorer 1500 v2 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery Explorer 1500 Ultra | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery HomePower 2000 Plus v2 | Check with manufacturer | Check with manufacturer | Direct DC8020 fit | — |
| Jackery HomePower 3000 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery HomePower 3600 Plus | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| BLUETTI AC2A | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| EcoFlow RIVER 3 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| EcoFlow RIVER 2 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Anker 521 PowerHouse | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| BLUETTI EB3A | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Pecron E300LFP | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Goal Zero Yeti 300 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| BLUETTI AC60 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| BLUETTI AC50B | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Goal Zero Yeti 500X | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Goal Zero Yeti 500 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| EcoFlow RIVER 2 Max | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Anker 535 PowerHouse | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Pecron E500LFP | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| EcoFlow RIVER 2 Pro | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Goal Zero Yeti 1000X | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Anker SOLIX C1000 Gen 2 | Check with manufacturer | Check with manufacturer | Adapter needed (DC8020 → XT60) | — |
| EcoFlow DELTA 3 Classic | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| EcoFlow DELTA 3 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Anker 757 PowerHouse | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| BLUETTI AC240 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Anker SOLIX C2000 Gen 2 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| BLUETTI AC200MAX | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Anker SOLIX F2600 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| BLUETTI Apex 300 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Goal Zero Yeti 3000X | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| EcoFlow DELTA 3 Ultra | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Anker SOLIX F3000 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Pecron F3000LFP | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| EcoFlow DELTA Pro | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Anker SOLIX F3800 | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Pecron F5000LFP | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Goal Zero Yeti 6000X | Check with manufacturer | Check with manufacturer | Station solar voltage/current limits not published in full | — |
| Jackery Explorer 300 Plus | Incompatible (Over-voltage) | 0 panels (over-voltage) | Direct DC8020 fit | — |
| BLUETTI Elite 30 V2 | Incompatible (Over-voltage) | 0 panels (over-voltage) | Adapter needed (DC8020 → XT60) | — |
| Anker SOLIX C300 | Incompatible (Over-voltage) | 0 panels (over-voltage) | Adapter needed (DC8020 → XT60) | — |
| DJI Power 500 | Incompatible (Over-voltage) | 0 panels (over-voltage) | Requires DJI Power Solar Panel Adapter Module (MPPT) + DC8020→XT60 cable | — |
| Goal Zero Yeti 700 | Incompatible (Over-voltage) | 0 panels (over-voltage) | Adapter needed (DC8020 → DC7909) | — |
| DJI Power 1000 | Incompatible (Over-voltage) | 0 panels (over-voltage) | Requires DJI Power Solar Panel Adapter Module (MPPT) + DC8020→XT60 cable | — |
| DJI Power 1000 V2 | Incompatible (Over-voltage) | 0 panels (over-voltage) | Requires DJI Power Solar Panel Adapter Module (MPPT) + DC8020→XT60 cable | — |
| DJI Power 2000 | Incompatible (Over-voltage) | 0 panels (over-voltage) | Requires DJI Power Solar Panel Adapter Module (MPPT) + DC8020→XT60 cable | — |
Notes from the source pages
- Comprises six 85 W panels wired in parallel. Product page warns: supports parallel connection only; do not connect in series and do not exceed six panels per DC8020 port.