Appliance runtime · surge check · checked November 22, 2026

Will a portable power station run a home refrigerator? Startup watts and how long it lasts

A modern full-size home refrigerator averages only 150–250 W while cooling and runs roughly a third of the day, so a 1,000–2,000 Wh station can keep food cold overnight—as long as its inverter clears the compressor's startup surge.

Cited wattages & electrical specs

Every figure below links to the manufacturer or official reference page where it was read on November 22, 2026.

Cited electrical specifications for Home refrigerator
Specification Published value Notes Source
Top-freezer fridge (14–18 cu ft) 100–200 W running · 400–600 W surge (0.8–1.6 kWh/day) Based on Jackery's ~1/3 compressor duty-cycle estimate; EcoFlow cites 150–400 W running for top-freezer models. jackery.com checked 2026-11-22
Bottom-freezer / Side-by-side (18–28 cu ft) 150–400 W running · 600–1,200 W surge (1.2–3.2 kWh/day) French-door units (20–30 cu ft) can reach 200–500 W running and 800–1,500 W surge. jackery.com checked 2026-11-22
Typical ENERGY STAR daily energy 1.0–2.0 kWh/day (~1.82 kWh/day avg); up to 4 kWh/day older EcoFlow cites 2–3× running watts at startup (up to 2,400 W on large units) and ~1.82 kWh/day typical residential use. ecoflow.com checked 2026-11-22
ENERGY STAR certified refrigerator baseline ~350–700+ kWh/yr (≈ 0.96–1.92 kWh/day) Divide the yellow EnergyGuide kWh/year figure by 365 for your model's average Wh/day baseline before outage door openings. energystar.gov checked 2026-11-22

How our estimate works & what to watch

Same defaults as the runtime calculator: 90% depth of discharge, 85% AC inverter efficiency, 95% DC efficiency.

Compressor duty cycle (~35% planning assumption) The share of each hour an appliance actually draws its running watts (for example, 35% means a fridge compressor runs about 21 minutes per hour on average). Changing duty cycle scales runtime proportionally.

Home refrigerators cycle on and off rather than pulling running watts 24/7. A 35% duty cycle is a planning assumption (matching ~1/3 runtime in Jackery's table) rather than a spec-sheet number—hot kitchens, warm groceries, or frequent door openings raise duty cycle.

Startup surge & defrost heaters The brief electrical spike when an electric motor or compressor starts from a stop. Resistive-boost modes (X-Boost, Power Lifting, SurgePad) are not motor surge ratings and are excluded from surge pass/fail checks.

Traditional single-speed compressors draw 2–3× running watts for a fraction of a second on startup (variable-speed inverter compressors spike less). Automatic defrost heaters can also draw 300–600 W briefly. Stations below the cited startup wattage are flagged.

Inverter idle draw over 24+ hours Keeping the AC inverter switched on uses standby power even between cycles or under light loads, so very small loads can drain a station slightly faster in practice than pure watt-hour math predicts.

Because the AC inverter stays powered on between compressor cycles so the fridge can restart automatically, standby inverter draw reduces multi-day runtime slightly compared to pure watt-hour math. Keeping doors closed helps far more than any setting.

Prefilled Home refrigerator runtime calculator

Preloaded with our cited home refrigerator baseline. Switch scenarios, pick any catalog station, or enter the watts from your own appliance label.

Open in full calculator

Station

Nameplate 268.8 Wh. Continuous 600 W. Surge 1200 W. Spec sheet.

Assumptions

Depth of discharge is the share of nameplate watt-hours treated as usable. The default is 90% because spec sheets usually publish nameplate capacity, not the watt-hours the battery management system delivers on every cycle. Change it if you want a more conservative or more optimistic plan.

Loads

Planning baseline from cited specs. Replace watts, duty %, and startup W with the label on your own unit.

Full-size home fridge

How long each catalog station runs it (85 models)

Computed with the shared calculator formula (90% DoD, 85% AC / 95% DC efficiency). 42 of 85 models meet the primary scenario's published output and port checks.

Showing all 85 models
Catalog runtime table for Home refrigerator
Station Standard · 150 W (35% est. duty, 1,200 W surge) Calculation assumption: 150 W running at an assumed 35% compressor duty cycle (≈ 1.26 kWh/day at load) with a cited 1,200 W startup surge check. Formula: (Wh × 90%) ÷ (W × duty ÷ 85%). Large French-door · 250 W (35% est. duty, 1,500 W surge) Calculation assumption: 250 W running at an assumed 35% duty cycle inside Jackery's 200–500 W running and 800–1,500 W surge ranges. Compatibility The brief electrical spike when an electric motor or compressor starts from a stop. Resistive-boost modes (X-Boost, Power Lifting, SurgePad) are not motor surge ratings and are excluded from surge pass/fail checks. Calculator
BLUETTI EB3A 268.8 Wh · 600 W AC · 1,200 W surge 3 h 55 min 3.92 hours 2 h 21 min Surge too low Fits spec Published 1,200 W surge clears 1,200 W startup. Prefill
Goal Zero Yeti 500X 497 Wh · 300 W AC · 1,200 W surge 7 h 15 min 7.24 hours 4 h 21 min Surge too low Fits spec Published 1,200 W surge clears 1,200 W startup. Prefill
EcoFlow RIVER 3 Max 572 Wh · 600 W AC · 1,200 W surge 8 h 20 min 8.33 hours 5 h Surge too low Fits spec Published 1,200 W surge clears 1,200 W startup. Prefill
BLUETTI AC70 768 Wh · 1,000 W AC · 1,500 W surge 11 h 11 min 11.19 hours 6 h 43 min 6.71 hours Fits spec Published 1,500 W surge clears 1,200 W startup. Prefill
BLUETTI AC70P 864 Wh · 1,000 W AC · 2,000 W surge 12 h 35 min 12.59 hours 7 h 33 min 7.55 hours Fits spec Published 2,000 W surge clears 1,200 W startup. Prefill
Pecron F1000LFP 960 Wh · 1,500 W AC · 3,000 W surge 13 h 59 min 13.99 hours 8 h 24 min 8.39 hours Fits spec Published 3,000 W surge clears 1,200 W startup. Prefill
Goal Zero Yeti 1000X 997 Wh · 1,500 W AC · 3,000 W surge 14 h 32 min 14.53 hours 8 h 43 min 8.72 hours Fits spec Published 3,000 W surge clears 1,200 W startup. Prefill
Goal Zero Yeti 1000 998.4 Wh · 2,000 W AC · 3,600 W surge 14 h 33 min 14.55 hours 8 h 44 min 8.73 hours Fits spec Published 3,600 W surge clears 1,200 W startup. Prefill
EcoFlow DELTA 2 1,024 Wh · 1,800 W AC · 2,700 W surge 14 h 55 min 14.92 hours 8 h 57 min 8.95 hours Fits spec Published 2,700 W surge clears 1,200 W startup. Prefill
EcoFlow DELTA 3 Plus 1,024 Wh · 1,800 W AC · 3,600 W surge 14 h 55 min 14.92 hours 8 h 57 min 8.95 hours Fits spec Published 3,600 W surge clears 1,200 W startup. Prefill
Anker SOLIX C1000 Gen 2 1,024 Wh · 2,000 W AC · 3,000 W surge 14 h 55 min 14.92 hours 8 h 57 min 8.95 hours Fits spec Published 3,000 W surge clears 1,200 W startup. Prefill
DJI Power 1000 1,024 Wh · 2,200 W AC · 4,400 W surge 14 h 55 min 14.92 hours 8 h 57 min 8.95 hours Fits spec Published 4,400 W surge clears 1,200 W startup. Prefill
Pecron E1000LFP 1,024 Wh · 1,800 W AC · 3,000 W surge 14 h 55 min 14.92 hours 8 h 57 min 8.95 hours Fits spec Published 3,000 W surge clears 1,200 W startup. Prefill
EcoFlow DELTA 3 Classic 1,024 Wh · 1,800 W AC · 3,600 W surge 14 h 55 min 14.92 hours 8 h 57 min 8.95 hours Fits spec Published 3,600 W surge clears 1,200 W startup. Prefill
Jackery Explorer 1000 v2 1,070 Wh · 1,500 W AC · 3,000 W surge 15 h 35 min 15.59 hours 9 h 21 min 9.35 hours Fits spec Published 3,000 W surge clears 1,200 W startup. Prefill
BLUETTI AC180 1,152 Wh · 1,800 W AC · 2,700 W surge 16 h 47 min 16.79 hours 10 h 4 min 10.07 hours Fits spec Published 2,700 W surge clears 1,200 W startup. Prefill
Jackery Explorer 1000 Plus 1,264.64 Wh · 2,000 W AC · 4,000 W surge 18 h 26 min 18.43 hours 11 h 3 min 11.06 hours Fits spec Published 4,000 W surge clears 1,200 W startup. Prefill
BLUETTI AC180P 1,440 Wh · 1,800 W AC · 2,700 W surge 20 h 59 min 20.98 hours 12 h 35 min 12.59 hours Fits spec Published 2,700 W surge clears 1,200 W startup. Prefill
Goal Zero Yeti 1500 1,505.28 Wh · 2,000 W AC · 3,600 W surge 21 h 56 min 21.93 hours 13 h 10 min 13.16 hours Fits spec Published 3,600 W surge clears 1,200 W startup. Prefill
Pecron E1500LFP 1,536 Wh · 2,200 W AC · 4,400 W surge 22 h 23 min 22.38 hours 13 h 26 min 13.43 hours Fits spec Published 4,400 W surge clears 1,200 W startup. Prefill
Jackery Explorer 1500 v2 1,536 Wh · 2,000 W AC · 4,000 W surge 22 h 23 min 22.38 hours 13 h 26 min 13.43 hours Fits spec Published 4,000 W surge clears 1,200 W startup. Prefill
Anker SOLIX S2000 2,010 Wh · 1,500 W AC · 3,000 W surge 29 h 17 min 29.29 hours 17 h 34 min 17.57 hours Fits spec Published 3,000 W surge clears 1,200 W startup. Prefill
Jackery Explorer 2000 v2 2,042 Wh · 2,200 W AC · 4,400 W surge 29 h 45 min 29.75 hours 17 h 51 min 17.85 hours Fits spec Published 4,400 W surge clears 1,200 W startup. Prefill
Jackery Explorer 2000 Plus 2,042.8 Wh · 3,000 W AC · 6,000 W surge 29 h 46 min 29.77 hours 17 h 52 min 17.86 hours Fits spec Published 6,000 W surge clears 1,200 W startup. Prefill
EcoFlow DELTA 2 Max 2,048 Wh · 2,400 W AC · 4,800 W surge 29 h 51 min 29.84 hours 17 h 54 min 17.91 hours Fits spec Published 4,800 W surge clears 1,200 W startup. Prefill
Anker SOLIX C2000 Gen 2 2,048 Wh · 2,400 W AC · 4,000 W surge 29 h 51 min 29.84 hours 17 h 54 min 17.91 hours Fits spec Published 4,000 W surge clears 1,200 W startup. Prefill
EcoFlow DELTA 3 Max 2,048 Wh · 2,400 W AC · 4,800 W surge 29 h 51 min 29.84 hours 17 h 54 min 17.91 hours Fits spec Published 4,800 W surge clears 1,200 W startup. Prefill
EcoFlow DELTA 3 Max Plus 2,048 Wh · 3,000 W AC · 6,000 W surge 29 h 51 min 29.84 hours 17 h 54 min 17.91 hours Fits spec Published 6,000 W surge clears 1,200 W startup. Prefill
Pecron E2400LFP 2,048 Wh · 2,400 W AC · 4,000 W surge 29 h 51 min 29.84 hours 17 h 54 min 17.91 hours Fits spec Published 4,000 W surge clears 1,200 W startup. Prefill
Anker SOLIX F2600 2,560 Wh · 2,400 W AC · 2,800 W surge 37 h 18 min 37.30 hours 22 h 23 min 22.38 hours Fits spec Published 2,800 W surge clears 1,200 W startup. Prefill
BLUETTI Elite 300 3,014.4 Wh · 2,400 W AC · 4,800 W surge 43 h 55 min 43.92 hours 26 h 21 min 26.35 hours Fits spec Published 4,800 W surge clears 1,200 W startup. Prefill
Goal Zero Yeti 3000X 3,032 Wh · 2,000 W AC · 3,500 W surge 44 h 11 min 44.18 hours 26 h 31 min 26.51 hours Fits spec Published 3,500 W surge clears 1,200 W startup. Prefill
Pecron E3600LFP 3,072 Wh · 3,600 W AC · 7,000 W surge 44 h 46 min 44.76 hours 26 h 51 min 26.86 hours Fits spec Published 7,000 W surge clears 1,200 W startup. Prefill
EcoFlow DELTA 3 Ultra 3,072 Wh · 3,600 W AC · 7,200 W surge 44 h 46 min 44.76 hours 26 h 51 min 26.86 hours Fits spec Published 7,200 W surge clears 1,200 W startup. Prefill
Jackery HomePower 3000 3,072 Wh · 3,600 W AC · 7,200 W surge 44 h 46 min 44.76 hours 26 h 51 min 26.86 hours Fits spec Published 7,200 W surge clears 1,200 W startup. Prefill
Pecron F3000LFP 3,072 Wh · 3,600 W AC · 4,500 W surge 44 h 46 min 44.76 hours 26 h 51 min 26.86 hours Fits spec Published 4,500 W surge clears 1,200 W startup. Prefill
Jackery HomePower 3600 Plus 3,584 Wh · 3,600 W AC · 7,200 W surge 52 h 13 min 52.22 hours 31 h 20 min 31.33 hours Fits spec Published 7,200 W surge clears 1,200 W startup. Prefill
EcoFlow DELTA Pro 3,600 Wh · 3,600 W AC · 7,200 W surge 52 h 27 min 52.46 hours 31 h 28 min 31.47 hours Fits spec Published 7,200 W surge clears 1,200 W startup. Prefill
Anker SOLIX F3800 Plus 3,840 Wh · 6,000 W AC · 9,000 W surge 55 h 57 min 55.95 hours 33 h 34 min 33.57 hours Fits spec Published 9,000 W surge clears 1,200 W startup. Prefill
EcoFlow DELTA Pro 3 4,096 Wh · 4,000 W AC · 8,000 W surge 59 h 41 min 59.68 hours 35 h 49 min 35.81 hours Fits spec Published 8,000 W surge clears 1,200 W startup. Prefill
Jackery Explorer 5000 Plus 5,040 Wh · 7,200 W AC · 14,400 W surge 73 h 26 min 73.44 hours 44 h 4 min 44.06 hours Fits spec Published 14,400 W surge clears 1,200 W startup. Prefill
Goal Zero Yeti 6000X 6,071 Wh · 2,000 W AC · 3,500 W surge 88 h 28 min 88.46 hours 53 h 5 min 53.08 hours Fits spec Published 3,500 W surge clears 1,200 W startup. Prefill
BLUETTI AC2A 204.8 Wh · 300 W AC 2 h 59 min 2.98 hours 1 h 47 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). 600 W resistive boost is not motor surge. Prefill
EcoFlow RIVER 3 245 Wh · 300 W AC 3 h 34 min 3.57 hours 2 h 9 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
EcoFlow RIVER 2 256 Wh · 300 W AC 3 h 44 min 3.73 hours 2 h 14 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). 600 W resistive boost is not motor surge. Prefill
Anker 521 PowerHouse 256 Wh · 200 W AC 3 h 44 min 3.73 hours 2 h 14 min Over continuous W Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
EcoFlow RIVER 3 Plus 286 Wh · 600 W AC 4 h 10 min 4.17 hours 2 h 30 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). 1,200 W resistive boost is not motor surge. Prefill
BLUETTI Elite 30 V2 288 Wh · 600 W AC 4 h 12 min 4.20 hours 2 h 31 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). 1,500 W resistive boost is not motor surge. Prefill
Pecron E300LFP 288 Wh · 600 W AC 4 h 12 min 4.20 hours 2 h 31 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
BLUETTI AC60 403.2 Wh · 600 W AC 5 h 53 min 5.88 hours 3 h 32 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
BLUETTI AC50B 448 Wh · 700 W AC 6 h 32 min 6.53 hours 3 h 55 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). 1,000 W resistive boost is not motor surge. Prefill
EcoFlow RIVER 2 Max 512 Wh · 500 W AC 7 h 28 min 7.46 hours 4 h 29 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). 1,000 W resistive boost is not motor surge. Prefill
Anker 535 PowerHouse 512 Wh · 500 W AC 7 h 28 min 7.46 hours 4 h 29 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
DJI Power 500 512 Wh · 1,000 W AC 7 h 28 min 7.46 hours 4 h 29 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
Jackery Explorer 500 518 Wh · 500 W AC 7 h 33 min 7.55 hours 4 h 32 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
Pecron E500LFP 576 Wh · 600 W AC 8 h 24 min 8.39 hours 5 h 2 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
Anker SOLIX C800 Plus 768 Wh · 1,200 W AC 11 h 11 min 11.19 hours 6 h 43 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). 1,600 W resistive boost is not motor surge. Prefill
EcoFlow RIVER 2 Pro 768 Wh · 800 W AC 11 h 11 min 11.19 hours 6 h 43 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). 1,600 W resistive boost is not motor surge. Prefill
BLUETTI Elite 100 V2 1,024 Wh · 1,800 W AC 14 h 55 min 14.92 hours 8 h 57 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). 2,700 W resistive boost is not motor surge. Prefill
DJI Power 1000 V2 1,024 Wh · 2,600 W AC 14 h 55 min 14.92 hours 8 h 57 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
EcoFlow DELTA 3 1,024 Wh · 1,800 W AC 14 h 55 min 14.92 hours 8 h 57 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
Jackery HomePower 1000 Plus v2 1,024 Wh · 1,800 W AC 14 h 55 min 14.92 hours 8 h 57 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
Anker SOLIX C1000 1,056 Wh · 1,800 W AC 15 h 23 min 15.39 hours 9 h 14 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). 2,400 W resistive boost is not motor surge. Prefill
Anker 757 PowerHouse 1,229 Wh · 1,500 W AC 17 h 54 min 17.91 hours 10 h 45 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
Jackery Explorer 1500 Ultra 1,536 Wh · 1,800 W AC 22 h 23 min 22.38 hours 13 h 26 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
BLUETTI AC240 1,536 Wh · 2,400 W AC 22 h 23 min 22.38 hours 13 h 26 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). 3,600 W resistive boost is not motor surge. Prefill
Jackery HomePower 2000 Plus v2 2,048 Wh · 2,400 W AC 29 h 51 min 29.84 hours 17 h 54 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
BLUETTI AC200L 2,048 Wh · 2,400 W AC 29 h 51 min 29.84 hours 17 h 54 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). 3,600 W resistive boost is not motor surge. Prefill
Anker SOLIX F2000 2,048 Wh · 2,400 W AC 29 h 51 min 29.84 hours 17 h 54 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). 3,600 W resistive boost is not motor surge. Prefill
DJI Power 2000 2,048 Wh · 3,000 W AC 29 h 51 min 29.84 hours 17 h 54 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
BLUETTI AC200MAX 2,048 Wh · 2,200 W AC 29 h 51 min 29.84 hours 17 h 54 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
BLUETTI Elite 200 V2 2,073.6 Wh · 2,600 W AC 30 h 13 min 30.22 hours 18 h 8 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). 3,900 W resistive boost is not motor surge. Prefill
BLUETTI Apex 300 2,764.8 Wh · 3,840 W AC 40 h 17 min 40.29 hours 24 h 10 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
Anker SOLIX F3000 3,072 Wh · 3,600 W AC 44 h 46 min 44.76 hours 26 h 51 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
Anker SOLIX F3800 3,840 Wh · 6,000 W AC 55 h 57 min 55.95 hours 33 h 34 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
Pecron E3800LFP 3,840 Wh · 4,200 W AC 55 h 57 min 55.95 hours 33 h 34 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
Pecron F5000LFP 5,120 Wh · 7,200 W AC 74 h 36 min 74.61 hours 44 h 46 min Surge unstated Surge unstated Surge rating not published (needs ~1,200 W startup). Prefill
Jackery Explorer 240 v2 256 Wh · 300 W AC · 600 W surge 3 h 44 min 3.73 hours 2 h 14 min Surge too low Surge too low Published surge (600 W) is below cited 1,200 W startup. Prefill
Jackery Explorer 300 Plus 288 Wh · 300 W AC · 600 W surge 4 h 12 min 4.20 hours 2 h 31 min Surge too low Surge too low Published surge (600 W) is below cited 1,200 W startup. Prefill
Anker SOLIX C300 288 Wh · 300 W AC · 600 W surge 4 h 12 min 4.20 hours 2 h 31 min Surge too low Surge too low Published surge (600 W) is below cited 1,200 W startup. Prefill
Jackery Explorer 300 293 Wh · 300 W AC · 500 W surge 4 h 16 min 4.27 hours 2 h 34 min Surge too low Surge too low Published surge (500 W) is below cited 1,200 W startup. Prefill
Goal Zero Yeti 300 296.96 Wh · 350 W AC · 600 W surge 4 h 20 min 4.33 hours 2 h 36 min Surge too low Surge too low Published surge (600 W) is below cited 1,200 W startup. Prefill
Goal Zero Yeti 500 499.2 Wh · 500 W AC · 1,000 W surge 7 h 16 min 7.27 hours 4 h 22 min Surge too low Surge too low Published surge (1,000 W) is below cited 1,200 W startup. Prefill
Jackery Explorer 600 v2 640 Wh · 500 W AC · 1,000 W surge 9 h 20 min 9.33 hours 5 h 36 min Surge too low Surge too low Published surge (1,000 W) is below cited 1,200 W startup. Prefill
Goal Zero Yeti 700 677.37 Wh · 600 W AC · 1,000 W surge 9 h 52 min 9.87 hours 5 h 55 min Surge too low Surge too low Published surge (1,000 W) is below cited 1,200 W startup. Prefill

Worked station examples

Calculated with the exact same shared runtime function as the interactive tool above.

EcoFlow

EcoFlow DELTA 2

14 h 55 min (14.92 hours) on Standard · 150 W (35% est. duty, 1,200 W surge) — Fits spec.

1,024 Wh capacity, 1,800 W continuous AC, and 2,700 W surge easily clear the 1,200 W startup check.

Jackery

Jackery Explorer 1000 v2

15 h 35 min (15.59 hours) on Standard · 150 W (35% est. duty, 1,200 W surge) — Fits spec.

1,070 Wh capacity, 1,500 W continuous AC, and 3,000 W surge cover an overnight outage with margin.

Common questions

Will a 600 W power station run a full-size refrigerator?
Often not reliably. While 600 W continuous covers ~150–250 W running draw, compact 300–600 W packs typically have 600–1,200 W surge ceilings that sit right at or below many full-size compressor startup spikes—and 300–600 Wh capacity lasts only a few hours.
How long will a 1,000 Wh station (like Jackery 1000 v2 or EcoFlow DELTA 2) run a home fridge?
Under the standard planning preset (150 W running, 35% duty, 90% DoD, 85% inverter efficiency), a ~1,024–1,070 Wh station estimates roughly 15–16 hours—enough for an overnight outage, though multi-day outages need 2,000+ Wh or solar/wall recharging.

Relevant stations, comparisons & guides

Check full manufacturer spec sheets, compare models side-by-side, or read the broader use-case guide.

EcoFlow

EcoFlow DELTA 2

  • Capacity:1,024 Wh
  • Continuous AC:1,800 W
  • Weight:27 lb
  • Chemistry:LFP

Est. Standard · 150 W (35% est. duty, 1,200 W surge): 14 h 55 min (Fits spec)

EcoFlow DELTA 2: 1,024 Wh, LFP, 1,800 W continuous AC, 2,700 W surge.

Jackery

Jackery Explorer 1000 v2

  • Capacity:1,070 Wh
  • Continuous AC:1,500 W
  • Weight:23.8 lb
  • Chemistry:LiFePO4

Est. Standard · 150 W (35% est. duty, 1,200 W surge): 15 h 35 min (Fits spec)

Jackery Explorer 1000 v2: 1,070 Wh, LiFePO4, 1,500 W continuous AC, 3,000 W surge.

EcoFlow

EcoFlow DELTA 2 Max

  • Capacity:2,048 Wh
  • Continuous AC:2,400 W
  • Weight:≈ 50.7 lb
  • Chemistry:LFP

Est. Standard · 150 W (35% est. duty, 1,200 W surge): 29 h 51 min (Fits spec)

EcoFlow DELTA 2 Max: 2,048 Wh, LFP, 2,400 W continuous AC, 4,800 W surge.

Sources & methodology

Appliance specifications checked November 22, 2026. Station check dates appear on the linked model pages.

How runtime and surge checks are computed: Methodology.