Appliance runtime · UPS ≤20 ms · checked November 22, 2026

Will a power station run a home office or gaming PC? UPS ≤20 ms & runtime

Running a home office or gaming PC during a blackout comes down to two things: total desk watts and whether the station's UPS/EPS switchover (≤20 ms) is fast enough to keep your desktop PSU from rebooting when grid power drops.

Cited wattages & electrical specs

Every figure below links to the manufacturer or official reference page where it was read on November 22, 2026.

Cited electrical specifications for Home office / gaming PC
Specification Published value Notes Source
Intel ATX 3.0 / 3.1 PSU hold-up time (T5+T6) >17 ms at 100% load (ATX 3.0) · >12 ms at 100% / 17 ms at 80% (ATX 3.1) Explains why desktop PCs target ≤20 ms (and preferably ≤10 ms) UPS switchover so PSU capacitors bridge the AC interruption without rebooting. intel.com checked 2026-11-22
ENERGY STAR certified computers & displays TEC (kWh/yr) & On-mode display watts Office laptops and mini-PCs draw far less than full-tower desktops; pair with display on-mode power for your exact desk load. energystar.gov checked 2026-11-22
ENERGY STAR certified displays On-mode & sleep watts by screen size Official ENERGY STAR database for monitor active and sleep wattage. energystar.gov checked 2026-11-22
NVIDIA GeForce RTX 40-Series GPU power 115–450 W GPU TGP · 550–850 W recommended PSU Mid-range cards like RTX 4060 (115 W TGP) and RTX 4070 (200 W TGP) explain why a gaming rig under load draws ~350–500 W even on a 650 W PSU. nvidia.com checked 2026-11-22

How our estimate works & what to watch

Same defaults as the runtime calculator: 90% depth of discharge, 85% AC inverter efficiency, 95% DC efficiency.

UPS switchover ≤20 ms vs. true online UPS (0 ms) Inverter efficiency is the share of battery energy that reaches an AC appliance. The default is 85%. Real efficiency changes with load and temperature, and most spec sheets in this dataset do not publish a single efficiency number.

Most portable power stations use offline/standby transfer (10–20 ms), not 0 ms double-conversion. Active PFC desktop PSUs vary in hold-up time, so test a simulated wall unplug after saving your work—especially for 20 ms units.

PSU rating ≠ wall draw The share of each hour an appliance actually draws its running watts (for example, 35% means a fridge compressor runs about 21 minutes per hour on average). Changing duty cycle scales runtime proportionally.

A 750 W or 1,000 W PC power supply only draws what the CPU, GPU, and drives demand at that moment—often 80–120 W at desktop idle and 350–550 W while gaming.

Pure sine wave & inverter idle draw Keeping the AC inverter switched on uses standby power even between cycles or under light loads, so very small loads can drain a station slightly faster in practice than pure watt-hour math predicts.

Modern LiFePO4 stations output pure sine wave AC required by Active PFC PSUs. For light 100 W office loads, standby inverter draw also trims a small fraction off ideal math.

Prefilled Home office / gaming PC runtime calculator

Preloaded with our cited home office / gaming pc baseline. Switch scenarios, pick any catalog station, or enter the watts from your own appliance label.

Open in full calculator

Station

Nameplate 288 Wh. Continuous 600 W. Surge not on file. Spec sheet. The spec sheet also lists a resistive-boost mode at 1500 W. That mode is not used as surge in this estimate.

Assumptions

Depth of discharge is the share of nameplate watt-hours treated as usable. The default is 90% because spec sheets usually publish nameplate capacity, not the watt-hours the battery management system delivers on every cycle. Change it if you want a more conservative or more optimistic plan.

Loads

Planning baseline from cited specs. Replace watts, duty %, and startup W with the label on your own unit.

Home office desk

How long each catalog station runs it (85 models)

Computed with the shared calculator formula (90% DoD, 85% AC / 95% DC efficiency). 23 of 85 models meet the primary scenario's published output and port checks.

Showing all 85 models
Catalog runtime table for Home office / gaming PC
Station Home office · 100 W est. (UPS ≤20 ms) Calculation assumption: 100 W combined AC load for a laptop or efficient desktop, monitor, and router (85% AC efficiency, 90% DoD). Checks whether published UPS switchover is ≤20 ms. Formula: (Wh × 90%) ÷ (W × duty ÷ 85%). Gaming PC · 450 W est. (UPS ≤20 ms) Calculation assumption: 450 W AC load representing a 200 W TGP GPU (such as RTX 4070) plus CPU, peripherals, and monitor under active gameplay, with UPS ≤20 ms check. Compatibility How fast the station switches from wall power to battery during an outage (ms). Faster switchover (such as ≤20 ms or <10 ms) helps keep desktop PCs from rebooting and matters when planning CPAP backup (always verify compatibility with your device manufacturer). Calculator
BLUETTI Elite 30 V2 288 Wh · 600 W AC · UPS ≤10 ms 2 h 12 min 2.20 hours 29 min 0.49 hours UPS ≤10 ms Published UPS switchover (≤10 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
Anker SOLIX C300 288 Wh · 300 W AC · 600 W surge · UPS <10 ms 2 h 12 min 2.20 hours 29 min Over continuous W UPS ≤10 ms Published UPS switchover (<10 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
EcoFlow RIVER 3 Max 572 Wh · 600 W AC · 1,200 W surge · UPS <10 ms 4 h 23 min 4.38 hours 58 min 0.97 hours UPS ≤10 ms Published UPS switchover (<10 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
BLUETTI AC70 768 Wh · 1,000 W AC · 1,500 W surge · UPS 20 ms 5 h 53 min 5.88 hours 1 h 18 min 1.31 hours UPS ≤20 ms Published UPS switchover (20 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
Anker SOLIX C800 Plus 768 Wh · 1,200 W AC · UPS 20 ms 5 h 53 min 5.88 hours 1 h 18 min 1.31 hours UPS ≤20 ms Published UPS switchover (20 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
BLUETTI AC70P 864 Wh · 1,000 W AC · 2,000 W surge · UPS ≤20 ms 6 h 37 min 6.61 hours 1 h 28 min 1.47 hours UPS ≤20 ms Published UPS switchover (≤20 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
Goal Zero Yeti 1000 998.4 Wh · 2,000 W AC · 3,600 W surge · UPS APS grid to battery in <15 ms 7 h 38 min 7.64 hours 1 h 42 min 1.70 hours UPS ≤15 ms Published UPS switchover (APS grid to battery in <15 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
BLUETTI Elite 100 V2 1,024 Wh · 1,800 W AC · UPS ≤10 ms 7 h 50 min 7.83 hours 1 h 44 min 1.74 hours UPS ≤10 ms Published UPS switchover (≤10 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
Anker SOLIX C1000 Gen 2 1,024 Wh · 2,000 W AC · 3,000 W surge · UPS under 10 ms 7 h 50 min 7.83 hours 1 h 44 min 1.74 hours UPS ≤10 ms Published UPS switchover (under 10 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
DJI Power 1000 V2 1,024 Wh · 2,600 W AC · UPS 0.01 s (UPS mode, FAQ) 7 h 50 min 7.83 hours 1 h 44 min 1.74 hours UPS ≤10 ms Published UPS switchover (0.01 s (UPS mode, FAQ)) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
Anker SOLIX C1000 1,056 Wh · 1,800 W AC · UPS 20 ms 8 h 5 min 8.08 hours 1 h 48 min 1.80 hours UPS ≤20 ms Published UPS switchover (20 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
BLUETTI AC180 1,152 Wh · 1,800 W AC · 2,700 W surge · UPS 20 ms 8 h 49 min 8.81 hours 1 h 58 min 1.96 hours UPS ≤20 ms Published UPS switchover (20 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
Goal Zero Yeti 1500 1,505.28 Wh · 2,000 W AC · 3,600 W surge · UPS APS grid to battery in <15 ms 11 h 31 min 11.52 hours 2 h 34 min 2.56 hours UPS ≤15 ms Published UPS switchover (APS grid to battery in <15 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
Anker SOLIX S2000 2,010 Wh · 1,500 W AC · 3,000 W surge · UPS ≤10 ms 15 h 23 min 15.38 hours 3 h 25 min 3.42 hours UPS ≤10 ms Published UPS switchover (≤10 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
Jackery Explorer 2000 Plus 2,042.8 Wh · 3,000 W AC · 6,000 W surge · UPS EPS within 20 ms 15 h 38 min 15.63 hours 3 h 28 min 3.47 hours UPS ≤20 ms Published UPS switchover (EPS within 20 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
BLUETTI AC200L 2,048 Wh · 2,400 W AC · UPS ≤20 ms 15 h 40 min 15.67 hours 3 h 29 min 3.48 hours UPS ≤20 ms Published UPS switchover (≤20 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
Anker SOLIX F2000 2,048 Wh · 2,400 W AC · UPS 20ms 15 h 40 min 15.67 hours 3 h 29 min 3.48 hours UPS ≤20 ms Published UPS switchover (20ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
DJI Power 2000 2,048 Wh · 3,000 W AC · UPS 0.01 s (UPS mode, store FAQ) 15 h 40 min 15.67 hours 3 h 29 min 3.48 hours UPS ≤10 ms Published UPS switchover (0.01 s (UPS mode, store FAQ)) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
EcoFlow DELTA 3 Max 2,048 Wh · 2,400 W AC · 4,800 W surge · UPS <10 ms 15 h 40 min 15.67 hours 3 h 29 min 3.48 hours UPS ≤10 ms Published UPS switchover (<10 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
EcoFlow DELTA 3 Max Plus 2,048 Wh · 3,000 W AC · 6,000 W surge · UPS <10 ms 15 h 40 min 15.67 hours 3 h 29 min 3.48 hours UPS ≤10 ms Published UPS switchover (<10 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
BLUETTI Elite 300 3,014.4 Wh · 2,400 W AC · 4,800 W surge · UPS ≤10 ms 23 h 4 min 23.06 hours 5 h 7 min 5.12 hours UPS ≤10 ms Published UPS switchover (≤10 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
Anker SOLIX F3800 Plus 3,840 Wh · 6,000 W AC · 9,000 W surge · UPS 20 ms 29 h 23 min 29.38 hours 6 h 32 min 6.53 hours UPS ≤20 ms Published UPS switchover (20 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
Jackery Explorer 5000 Plus 5,040 Wh · 7,200 W AC · 14,400 W surge · UPS UPS <20 ms; online UPS 0 ms 38 h 33 min 38.56 hours 8 h 34 min 8.57 hours UPS ≤20 ms Published UPS switchover (UPS <20 ms; online UPS 0 ms) meets the ≤20 ms threshold; confirm hold-up time with your PC PSU. Prefill
BLUETTI AC2A 204.8 Wh · 300 W AC 1 h 34 min 1.57 hours 21 min Over continuous W UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
EcoFlow RIVER 3 245 Wh · 300 W AC 1 h 52 min 1.87 hours 25 min Over continuous W UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
EcoFlow RIVER 2 256 Wh · 300 W AC 1 h 58 min 1.96 hours 26 min Over continuous W UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Jackery Explorer 240 v2 256 Wh · 300 W AC · 600 W surge 1 h 58 min 1.96 hours 26 min Over continuous W UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Anker 521 PowerHouse 256 Wh · 200 W AC 1 h 58 min 1.96 hours 26 min Over continuous W UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
BLUETTI EB3A 268.8 Wh · 600 W AC · 1,200 W surge 2 h 3 min 2.06 hours 27 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
EcoFlow RIVER 3 Plus 286 Wh · 600 W AC 2 h 11 min 2.19 hours 29 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Jackery Explorer 300 Plus 288 Wh · 300 W AC · 600 W surge 2 h 12 min 2.20 hours 29 min Over continuous W UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Pecron E300LFP 288 Wh · 600 W AC 2 h 12 min 2.20 hours 29 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Jackery Explorer 300 293 Wh · 300 W AC · 500 W surge 2 h 14 min 2.24 hours 30 min Over continuous W UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Goal Zero Yeti 300 296.96 Wh · 350 W AC · 600 W surge 2 h 16 min 2.27 hours 30 min Over continuous W UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
BLUETTI AC60 403.2 Wh · 600 W AC 3 h 5 min 3.08 hours 41 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
BLUETTI AC50B 448 Wh · 700 W AC 3 h 26 min 3.43 hours 46 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Goal Zero Yeti 500X 497 Wh · 300 W AC · 1,200 W surge 3 h 48 min 3.80 hours 51 min Over continuous W UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Goal Zero Yeti 500 499.2 Wh · 500 W AC · 1,000 W surge 3 h 49 min 3.82 hours 51 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
EcoFlow RIVER 2 Max 512 Wh · 500 W AC 3 h 55 min 3.92 hours 52 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Anker 535 PowerHouse 512 Wh · 500 W AC 3 h 55 min 3.92 hours 52 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
DJI Power 500 512 Wh · 1,000 W AC 3 h 55 min 3.92 hours 52 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Jackery Explorer 500 518 Wh · 500 W AC 3 h 58 min 3.96 hours 53 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Pecron E500LFP 576 Wh · 600 W AC 4 h 24 min 4.41 hours 59 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Jackery Explorer 600 v2 640 Wh · 500 W AC · 1,000 W surge 4 h 54 min 4.90 hours 1 h 5 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Goal Zero Yeti 700 677.37 Wh · 600 W AC · 1,000 W surge 5 h 11 min 5.18 hours 1 h 9 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
EcoFlow RIVER 2 Pro 768 Wh · 800 W AC 5 h 53 min 5.88 hours 1 h 18 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Pecron F1000LFP 960 Wh · 1,500 W AC · 3,000 W surge 7 h 21 min 7.34 hours 1 h 38 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Goal Zero Yeti 1000X 997 Wh · 1,500 W AC · 3,000 W surge 7 h 38 min 7.63 hours 1 h 42 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
EcoFlow DELTA 2 1,024 Wh · 1,800 W AC · 2,700 W surge 7 h 50 min 7.83 hours 1 h 44 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
EcoFlow DELTA 3 Plus 1,024 Wh · 1,800 W AC · 3,600 W surge 7 h 50 min 7.83 hours 1 h 44 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
DJI Power 1000 1,024 Wh · 2,200 W AC · 4,400 W surge 7 h 50 min 7.83 hours 1 h 44 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Pecron E1000LFP 1,024 Wh · 1,800 W AC · 3,000 W surge · UPS UPS function (bullets) 7 h 50 min 7.83 hours 1 h 44 min UPS ms unstated UPS ms unstated UPS mode is listed (UPS function (bullets)), but switchover milliseconds are not published; confirm ≤20 ms with the manufacturer. Prefill
EcoFlow DELTA 3 Classic 1,024 Wh · 1,800 W AC · 3,600 W surge 7 h 50 min 7.83 hours 1 h 44 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
EcoFlow DELTA 3 1,024 Wh · 1,800 W AC 7 h 50 min 7.83 hours 1 h 44 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Jackery HomePower 1000 Plus v2 1,024 Wh · 1,800 W AC 7 h 50 min 7.83 hours 1 h 44 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Jackery Explorer 1000 v2 1,070 Wh · 1,500 W AC · 3,000 W surge 8 h 11 min 8.19 hours 1 h 49 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Anker 757 PowerHouse 1,229 Wh · 1,500 W AC 9 h 24 min 9.40 hours 2 h 5 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Jackery Explorer 1000 Plus 1,264.64 Wh · 2,000 W AC · 4,000 W surge 9 h 40 min 9.67 hours 2 h 9 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
BLUETTI AC180P 1,440 Wh · 1,800 W AC · 2,700 W surge 11 h 1 min 11.02 hours 2 h 27 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Pecron E1500LFP 1,536 Wh · 2,200 W AC · 4,400 W surge · UPS UPS function (bullets) 11 h 45 min 11.75 hours 2 h 37 min UPS ms unstated UPS ms unstated UPS mode is listed (UPS function (bullets)), but switchover milliseconds are not published; confirm ≤20 ms with the manufacturer. Prefill
Jackery Explorer 1500 v2 1,536 Wh · 2,000 W AC · 4,000 W surge 11 h 45 min 11.75 hours 2 h 37 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Jackery Explorer 1500 Ultra 1,536 Wh · 1,800 W AC 11 h 45 min 11.75 hours 2 h 37 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
BLUETTI AC240 1,536 Wh · 2,400 W AC 11 h 45 min 11.75 hours 2 h 37 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Jackery Explorer 2000 v2 2,042 Wh · 2,200 W AC · 4,400 W surge 15 h 37 min 15.62 hours 3 h 28 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
EcoFlow DELTA 2 Max 2,048 Wh · 2,400 W AC · 4,800 W surge 15 h 40 min 15.67 hours 3 h 29 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Jackery HomePower 2000 Plus v2 2,048 Wh · 2,400 W AC 15 h 40 min 15.67 hours 3 h 29 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Anker SOLIX C2000 Gen 2 2,048 Wh · 2,400 W AC · 4,000 W surge 15 h 40 min 15.67 hours 3 h 29 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Pecron E2400LFP 2,048 Wh · 2,400 W AC · 4,000 W surge · UPS UPS function; UPS power 1800 W max 15 h 40 min 15.67 hours 3 h 29 min UPS ms unstated UPS ms unstated UPS mode is listed (UPS function; UPS power 1800 W max), but switchover milliseconds are not published; confirm ≤20 ms with the manufacturer. Prefill
BLUETTI AC200MAX 2,048 Wh · 2,200 W AC 15 h 40 min 15.67 hours 3 h 29 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
BLUETTI Elite 200 V2 2,073.6 Wh · 2,600 W AC 15 h 52 min 15.86 hours 3 h 32 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Anker SOLIX F2600 2,560 Wh · 2,400 W AC · 2,800 W surge 19 h 35 min 19.58 hours 4 h 21 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
BLUETTI Apex 300 2,764.8 Wh · 3,840 W AC 21 h 9 min 21.15 hours 4 h 42 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Goal Zero Yeti 3000X 3,032 Wh · 2,000 W AC · 3,500 W surge 23 h 12 min 23.19 hours 5 h 9 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Pecron E3600LFP 3,072 Wh · 3,600 W AC · 7,000 W surge · UPS UPS listed; UPS power 3600 W max with 30 A cable / 1800 W max with 15 A cable 23 h 30 min 23.50 hours 5 h 13 min UPS ms unstated UPS ms unstated UPS mode is listed (UPS listed; UPS power 3600 W max with 30 A cable / 1800 W max with 15 A cable), but switchover milliseconds are not published; confirm ≤20 ms with the manufacturer. Prefill
EcoFlow DELTA 3 Ultra 3,072 Wh · 3,600 W AC · 7,200 W surge 23 h 30 min 23.50 hours 5 h 13 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Jackery HomePower 3000 3,072 Wh · 3,600 W AC · 7,200 W surge 23 h 30 min 23.50 hours 5 h 13 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Anker SOLIX F3000 3,072 Wh · 3,600 W AC 23 h 30 min 23.50 hours 5 h 13 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Pecron F3000LFP 3,072 Wh · 3,600 W AC · 4,500 W surge 23 h 30 min 23.50 hours 5 h 13 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Jackery HomePower 3600 Plus 3,584 Wh · 3,600 W AC · 7,200 W surge 27 h 25 min 27.42 hours 6 h 6 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
EcoFlow DELTA Pro 3,600 Wh · 3,600 W AC · 7,200 W surge 27 h 32 min 27.54 hours 6 h 7 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Anker SOLIX F3800 3,840 Wh · 6,000 W AC 29 h 23 min 29.38 hours 6 h 32 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Pecron E3800LFP 3,840 Wh · 4,200 W AC 29 h 23 min 29.38 hours 6 h 32 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
EcoFlow DELTA Pro 3 4,096 Wh · 4,000 W AC · 8,000 W surge 31 h 20 min 31.33 hours 6 h 58 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Pecron F5000LFP 5,120 Wh · 7,200 W AC 39 h 10 min 39.17 hours 8 h 42 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill
Goal Zero Yeti 6000X 6,071 Wh · 2,000 W AC · 3,500 W surge 46 h 27 min 46.44 hours 10 h 19 min UPS unstated UPS unstated UPS switchover time is not published for this model; verify ≤20 ms switchover before relying on it for a desktop PC. Prefill

Worked station examples

Calculated with the exact same shared runtime function as the interactive tool above.

EcoFlow

EcoFlow DELTA 3 Max

15 h 40 min (15.67 hours) on Home office · 100 W est. (UPS ≤20 ms) — UPS ≤10 ms.

2,048 Wh with <10 ms UPS switchover keeps a 100 W home office online for ~15h 39m.

Anker

Anker SOLIX C1000 Gen 2

1 h 44 min (1.74 hours) on Gaming PC · 450 W est. (UPS ≤20 ms) — UPS ≤10 ms.

1,024 Wh with <10 ms UPS switchover and 2,000 W AC runs a 450 W gaming rig for ~1h 44m.

Common questions

Is a 20 ms UPS power station fast enough for a gaming PC?
Often yes for work/idle loads, but 20 ms sits right near the 12–20 ms hold-up limit of many Active PFC PSUs under heavy GPU load. Stations rated at ≤10 ms (or <10 ms) give extra margin; always test before relying on one.
How long will a 1,000 Wh station run a home office vs. a gaming PC?
At 90% DoD and 85% AC efficiency, a 1,024 Wh station runs a 100 W home office for ~7h 50m (a full workday) versus ~1h 44m on a 450 W gaming load.

Relevant stations, comparisons & guides

Check full manufacturer spec sheets, compare models side-by-side, or read the broader use-case guide.

EcoFlow

EcoFlow DELTA 3 Max

  • Capacity:2,048 Wh
  • Continuous AC:2,400 W
  • Weight:≈ 44.8 lb
  • Chemistry:LFP

Est. Home office · 100 W est. (UPS ≤20 ms): 15 h 40 min (UPS ≤10 ms)

EcoFlow DELTA 3 Max: 2,048 Wh, LFP (LiFePO4), 2,400 W continuous AC, 4,800 W surge.

BLUETTI

BLUETTI Elite 100 V2

  • Capacity:1,024 Wh
  • Continuous AC:1,800 W
  • Weight:25 lb
  • Chemistry:LiFePO4

Est. Home office · 100 W est. (UPS ≤20 ms): 7 h 50 min (UPS ≤10 ms)

BLUETTI Elite 100 V2: 1,024 Wh, LiFePO4, 1,800 W continuous AC.

Sources & methodology

Appliance specifications checked November 22, 2026. Station check dates appear on the linked model pages.

How runtime and surge checks are computed: Methodology.