Appliance runtime · compressor surge · checked November 22, 2026

Will a portable power station run a portable AC? Compressor surge & runtime

Portable air conditioners combine high continuous compressor draw (1,000 to 1,300 W on 12,000–14,000 BTU ASHRAE units) with a 2× to 3× startup surge on non-inverter compressors. Most 1,000 Wh stations last under an hour unless the compressor cycles off.

Cited wattages & electrical specs

Every figure below links to the manufacturer or official reference page where it was read on November 22, 2026.

Cited electrical specifications for Portable AC
Specification Published value Notes Source
Whynter ARC-12S (12,000 BTU ASHRAE portable AC) 1,000 W running (9.2 A, 115 V) Manufacturer electrical rating during compressor cooling; non-inverter compressors draw an additional startup surge. whynter.com checked 2026-11-22
Whynter ARC-14S (14,000 BTU ASHRAE / 9,500 BTU DOE) 1,300 W running (11.6 A, 115 V) Manufacturer electrical rating for a dual-hose unit; check DOE/SACC cooling vs. ASHRAE BTU. whynter.com checked 2026-11-22
ENERGY STAR room AC reference Certified room AC database Standalone portable ACs are regulated under DOE SACC standards rather than ENERGY STAR room AC certification. energystar.gov checked 2026-11-22

How our estimate works & what to watch

Same defaults as the runtime calculator: 90% depth of discharge, 85% AC inverter efficiency, 95% DC efficiency.

Assumed 2.5× compressor startup surge The brief electrical spike when an electric motor or compressor starts from a stop. Resistive-boost modes (X-Boost, Power Lifting, SurgePad) are not motor surge ratings and are excluded from surge pass/fail checks.

Manufacturers publish running watts/amps rather than locked-rotor startup spikes, so we apply an assumed 2.5× compressor surge check (2,500 W / 3,250 W) and exclude resistive boost.

Compressor duty cycle (70% assumption) The share of each hour an appliance actually draws its running watts (for example, 35% means a fridge compressor runs about 21 minutes per hour on average). Changing duty cycle scales runtime proportionally.

In hot afternoon weather, a portable AC compressor may run 70–100% of the time; at night in a shaded space, it cycles closer to 40–60%. Lowering duty % in the calculator scales runtime proportionally.

Battery capacity limits overnight cooling Depth of discharge is the share of nameplate watt-hours treated as usable. The default is 90% because spec sheets usually publish nameplate capacity, not the watt-hours the battery management system delivers on every cycle. Change it if you want a more conservative or more optimistic plan.

At 1,000 W running and 70% duty (700 W average AC load, ~824 W from the battery at 85% inverter efficiency), a 2,048 Wh station (~1,843 Wh usable at 90% DoD) runs ~2.2 hours. Overnight cooling requires 3,000–5,000+ Wh or an inverter-compressor unit.

Prefilled Portable AC runtime calculator

Preloaded with our cited portable ac baseline. Switch scenarios, pick any catalog station, or enter the watts from your own appliance label.

Open in full calculator

Station

Nameplate 960 Wh. Continuous 1500 W. Surge 3000 W. Spec sheet.

Assumptions

Depth of discharge is the share of nameplate watt-hours treated as usable. The default is 90% because spec sheets usually publish nameplate capacity, not the watt-hours the battery management system delivers on every cycle. Change it if you want a more conservative or more optimistic plan.

Loads

Planning baseline from cited specs. Replace watts, duty %, and startup W with the label on your own unit.

12,000 BTU ASHRAE portable AC

How long each catalog station runs it (85 models)

Computed with the shared calculator formula (90% DoD, 85% AC / 95% DC efficiency). 37 of 85 models meet the primary scenario's published output and port checks.

Showing all 85 models
Catalog runtime table for Portable AC
Station 12k ASHRAE · 1,000 W (2,500 W est. surge) Uses Whynter ARC-12S published 1,000 W running draw, with calculation assumptions of 70% compressor duty cycle and 2.5× (2,500 W) startup surge (85% AC efficiency, 90% DoD). Formula: (Wh × 90%) ÷ (W × duty ÷ 85%). 14k ASHRAE · 1,300 W (3,250 W est. surge) Uses Whynter ARC-14S published 1,300 W running draw, with calculation assumptions of 70% compressor duty cycle and 2.5× (3,250 W) startup surge. Compatibility The brief electrical spike when an electric motor or compressor starts from a stop. Resistive-boost modes (X-Boost, Power Lifting, SurgePad) are not motor surge ratings and are excluded from surge pass/fail checks. Calculator
Pecron F1000LFP 960 Wh · 1,500 W AC · 3,000 W surge 1 h 3 min 1.05 hours 48 min Surge too low Fits spec Published 3,000 W surge clears 2,500 W startup. Prefill
Goal Zero Yeti 1000X 997 Wh · 1,500 W AC · 3,000 W surge 1 h 5 min 1.09 hours 50 min Surge too low Fits spec Published 3,000 W surge clears 2,500 W startup. Prefill
Goal Zero Yeti 1000 998.4 Wh · 2,000 W AC · 3,600 W surge 1 h 5 min 1.09 hours 50 min 0.84 hours Fits spec Published 3,600 W surge clears 2,500 W startup. Prefill
EcoFlow DELTA 2 1,024 Wh · 1,800 W AC · 2,700 W surge 1 h 7 min 1.12 hours 52 min Surge too low Fits spec Published 2,700 W surge clears 2,500 W startup. Prefill
EcoFlow DELTA 3 Plus 1,024 Wh · 1,800 W AC · 3,600 W surge 1 h 7 min 1.12 hours 52 min 0.86 hours Fits spec Published 3,600 W surge clears 2,500 W startup. Prefill
Anker SOLIX C1000 Gen 2 1,024 Wh · 2,000 W AC · 3,000 W surge 1 h 7 min 1.12 hours 52 min Surge too low Fits spec Published 3,000 W surge clears 2,500 W startup. Prefill
DJI Power 1000 1,024 Wh · 2,200 W AC · 4,400 W surge 1 h 7 min 1.12 hours 52 min 0.86 hours Fits spec Published 4,400 W surge clears 2,500 W startup. Prefill
Pecron E1000LFP 1,024 Wh · 1,800 W AC · 3,000 W surge 1 h 7 min 1.12 hours 52 min Surge too low Fits spec Published 3,000 W surge clears 2,500 W startup. Prefill
EcoFlow DELTA 3 Classic 1,024 Wh · 1,800 W AC · 3,600 W surge 1 h 7 min 1.12 hours 52 min 0.86 hours Fits spec Published 3,600 W surge clears 2,500 W startup. Prefill
Jackery Explorer 1000 v2 1,070 Wh · 1,500 W AC · 3,000 W surge 1 h 10 min 1.17 hours 54 min Surge too low Fits spec Published 3,000 W surge clears 2,500 W startup. Prefill
BLUETTI AC180 1,152 Wh · 1,800 W AC · 2,700 W surge 1 h 16 min 1.26 hours 58 min Surge too low Fits spec Published 2,700 W surge clears 2,500 W startup. Prefill
Jackery Explorer 1000 Plus 1,264.64 Wh · 2,000 W AC · 4,000 W surge 1 h 23 min 1.38 hours 1 h 4 min 1.06 hours Fits spec Published 4,000 W surge clears 2,500 W startup. Prefill
BLUETTI AC180P 1,440 Wh · 1,800 W AC · 2,700 W surge 1 h 34 min 1.57 hours 1 h 13 min Surge too low Fits spec Published 2,700 W surge clears 2,500 W startup. Prefill
Goal Zero Yeti 1500 1,505.28 Wh · 2,000 W AC · 3,600 W surge 1 h 39 min 1.65 hours 1 h 16 min 1.27 hours Fits spec Published 3,600 W surge clears 2,500 W startup. Prefill
Pecron E1500LFP 1,536 Wh · 2,200 W AC · 4,400 W surge 1 h 41 min 1.68 hours 1 h 17 min 1.29 hours Fits spec Published 4,400 W surge clears 2,500 W startup. Prefill
Jackery Explorer 1500 v2 1,536 Wh · 2,000 W AC · 4,000 W surge 1 h 41 min 1.68 hours 1 h 17 min 1.29 hours Fits spec Published 4,000 W surge clears 2,500 W startup. Prefill
Anker SOLIX S2000 2,010 Wh · 1,500 W AC · 3,000 W surge 2 h 12 min 2.20 hours 1 h 41 min Surge too low Fits spec Published 3,000 W surge clears 2,500 W startup. Prefill
Jackery Explorer 2000 v2 2,042 Wh · 2,200 W AC · 4,400 W surge 2 h 14 min 2.23 hours 1 h 43 min 1.72 hours Fits spec Published 4,400 W surge clears 2,500 W startup. Prefill
Jackery Explorer 2000 Plus 2,042.8 Wh · 3,000 W AC · 6,000 W surge 2 h 14 min 2.23 hours 1 h 43 min 1.72 hours Fits spec Published 6,000 W surge clears 2,500 W startup. Prefill
EcoFlow DELTA 2 Max 2,048 Wh · 2,400 W AC · 4,800 W surge 2 h 14 min 2.24 hours 1 h 43 min 1.72 hours Fits spec Published 4,800 W surge clears 2,500 W startup. Prefill
Anker SOLIX C2000 Gen 2 2,048 Wh · 2,400 W AC · 4,000 W surge 2 h 14 min 2.24 hours 1 h 43 min 1.72 hours Fits spec Published 4,000 W surge clears 2,500 W startup. Prefill
EcoFlow DELTA 3 Max 2,048 Wh · 2,400 W AC · 4,800 W surge 2 h 14 min 2.24 hours 1 h 43 min 1.72 hours Fits spec Published 4,800 W surge clears 2,500 W startup. Prefill
EcoFlow DELTA 3 Max Plus 2,048 Wh · 3,000 W AC · 6,000 W surge 2 h 14 min 2.24 hours 1 h 43 min 1.72 hours Fits spec Published 6,000 W surge clears 2,500 W startup. Prefill
Pecron E2400LFP 2,048 Wh · 2,400 W AC · 4,000 W surge 2 h 14 min 2.24 hours 1 h 43 min 1.72 hours Fits spec Published 4,000 W surge clears 2,500 W startup. Prefill
Anker SOLIX F2600 2,560 Wh · 2,400 W AC · 2,800 W surge 2 h 48 min 2.80 hours 2 h 9 min Surge too low Fits spec Published 2,800 W surge clears 2,500 W startup. Prefill
BLUETTI Elite 300 3,014.4 Wh · 2,400 W AC · 4,800 W surge 3 h 18 min 3.29 hours 2 h 32 min 2.53 hours Fits spec Published 4,800 W surge clears 2,500 W startup. Prefill
Goal Zero Yeti 3000X 3,032 Wh · 2,000 W AC · 3,500 W surge 3 h 19 min 3.31 hours 2 h 33 min 2.55 hours Fits spec Published 3,500 W surge clears 2,500 W startup. Prefill
Pecron E3600LFP 3,072 Wh · 3,600 W AC · 7,000 W surge 3 h 21 min 3.36 hours 2 h 35 min 2.58 hours Fits spec Published 7,000 W surge clears 2,500 W startup. Prefill
EcoFlow DELTA 3 Ultra 3,072 Wh · 3,600 W AC · 7,200 W surge 3 h 21 min 3.36 hours 2 h 35 min 2.58 hours Fits spec Published 7,200 W surge clears 2,500 W startup. Prefill
Jackery HomePower 3000 3,072 Wh · 3,600 W AC · 7,200 W surge 3 h 21 min 3.36 hours 2 h 35 min 2.58 hours Fits spec Published 7,200 W surge clears 2,500 W startup. Prefill
Pecron F3000LFP 3,072 Wh · 3,600 W AC · 4,500 W surge 3 h 21 min 3.36 hours 2 h 35 min 2.58 hours Fits spec Published 4,500 W surge clears 2,500 W startup. Prefill
Jackery HomePower 3600 Plus 3,584 Wh · 3,600 W AC · 7,200 W surge 3 h 55 min 3.92 hours 3 h 1 min 3.01 hours Fits spec Published 7,200 W surge clears 2,500 W startup. Prefill
EcoFlow DELTA Pro 3,600 Wh · 3,600 W AC · 7,200 W surge 3 h 56 min 3.93 hours 3 h 2 min 3.03 hours Fits spec Published 7,200 W surge clears 2,500 W startup. Prefill
Anker SOLIX F3800 Plus 3,840 Wh · 6,000 W AC · 9,000 W surge 4 h 12 min 4.20 hours 3 h 14 min 3.23 hours Fits spec Published 9,000 W surge clears 2,500 W startup. Prefill
EcoFlow DELTA Pro 3 4,096 Wh · 4,000 W AC · 8,000 W surge 4 h 29 min 4.48 hours 3 h 27 min 3.44 hours Fits spec Published 8,000 W surge clears 2,500 W startup. Prefill
Jackery Explorer 5000 Plus 5,040 Wh · 7,200 W AC · 14,400 W surge 5 h 30 min 5.51 hours 4 h 14 min 4.24 hours Fits spec Published 14,400 W surge clears 2,500 W startup. Prefill
Goal Zero Yeti 6000X 6,071 Wh · 2,000 W AC · 3,500 W surge 6 h 38 min 6.63 hours 5 h 6 min 5.10 hours Fits spec Published 3,500 W surge clears 2,500 W startup. Prefill
DJI Power 500 512 Wh · 1,000 W AC 34 min 0.56 hours 26 min Over continuous W Surge unstated Surge rating not published (needs ~2,500 W startup). Prefill
Anker SOLIX C800 Plus 768 Wh · 1,200 W AC 50 min 0.84 hours 39 min Over continuous W Surge unstated Surge rating not published (needs ~2,500 W startup). 1,600 W resistive boost is not motor surge. Prefill
BLUETTI Elite 100 V2 1,024 Wh · 1,800 W AC 1 h 7 min 1.12 hours 52 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). 2,700 W resistive boost is not motor surge. Prefill
DJI Power 1000 V2 1,024 Wh · 2,600 W AC 1 h 7 min 1.12 hours 52 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). Prefill
EcoFlow DELTA 3 1,024 Wh · 1,800 W AC 1 h 7 min 1.12 hours 52 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). Prefill
Jackery HomePower 1000 Plus v2 1,024 Wh · 1,800 W AC 1 h 7 min 1.12 hours 52 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). Prefill
Anker SOLIX C1000 1,056 Wh · 1,800 W AC 1 h 9 min 1.15 hours 53 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). 2,400 W resistive boost is not motor surge. Prefill
Anker 757 PowerHouse 1,229 Wh · 1,500 W AC 1 h 21 min 1.34 hours 1 h 2 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). Prefill
Jackery Explorer 1500 Ultra 1,536 Wh · 1,800 W AC 1 h 41 min 1.68 hours 1 h 17 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). Prefill
BLUETTI AC240 1,536 Wh · 2,400 W AC 1 h 41 min 1.68 hours 1 h 17 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). 3,600 W resistive boost is not motor surge. Prefill
Jackery HomePower 2000 Plus v2 2,048 Wh · 2,400 W AC 2 h 14 min 2.24 hours 1 h 43 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). Prefill
BLUETTI AC200L 2,048 Wh · 2,400 W AC 2 h 14 min 2.24 hours 1 h 43 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). 3,600 W resistive boost is not motor surge. Prefill
Anker SOLIX F2000 2,048 Wh · 2,400 W AC 2 h 14 min 2.24 hours 1 h 43 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). 3,600 W resistive boost is not motor surge. Prefill
DJI Power 2000 2,048 Wh · 3,000 W AC 2 h 14 min 2.24 hours 1 h 43 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). Prefill
BLUETTI AC200MAX 2,048 Wh · 2,200 W AC 2 h 14 min 2.24 hours 1 h 43 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). Prefill
BLUETTI Elite 200 V2 2,073.6 Wh · 2,600 W AC 2 h 16 min 2.27 hours 1 h 45 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). 3,900 W resistive boost is not motor surge. Prefill
BLUETTI Apex 300 2,764.8 Wh · 3,840 W AC 3 h 1 min 3.02 hours 2 h 19 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). Prefill
Anker SOLIX F3000 3,072 Wh · 3,600 W AC 3 h 21 min 3.36 hours 2 h 35 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). Prefill
Anker SOLIX F3800 3,840 Wh · 6,000 W AC 4 h 12 min 4.20 hours 3 h 14 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). Prefill
Pecron E3800LFP 3,840 Wh · 4,200 W AC 4 h 12 min 4.20 hours 3 h 14 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). Prefill
Pecron F5000LFP 5,120 Wh · 7,200 W AC 5 h 36 min 5.60 hours 4 h 18 min Surge unstated Surge unstated Surge rating not published (needs ~2,500 W startup). Prefill
BLUETTI AC2A 204.8 Wh · 300 W AC 13 min 0.22 hours 10 min Over continuous W Over continuous W Running draw (1000 W) exceeds 300 W continuous AC rating. Prefill
EcoFlow RIVER 3 245 Wh · 300 W AC 16 min 0.27 hours 12 min Over continuous W Over continuous W Running draw (1000 W) exceeds 300 W continuous AC rating. Prefill
EcoFlow RIVER 2 256 Wh · 300 W AC 17 min 0.28 hours 13 min Over continuous W Over continuous W Running draw (1000 W) exceeds 300 W continuous AC rating. Prefill
Jackery Explorer 240 v2 256 Wh · 300 W AC · 600 W surge 17 min 0.28 hours 13 min Over continuous W Over continuous W Running draw (1000 W) exceeds 300 W continuous AC rating. Prefill
Anker 521 PowerHouse 256 Wh · 200 W AC 17 min 0.28 hours 13 min Over continuous W Over continuous W Running draw (1000 W) exceeds 200 W continuous AC rating. Prefill
BLUETTI EB3A 268.8 Wh · 600 W AC · 1,200 W surge 18 min 0.29 hours 14 min Over continuous W Over continuous W Running draw (1000 W) exceeds 600 W continuous AC rating. Prefill
EcoFlow RIVER 3 Plus 286 Wh · 600 W AC 19 min 0.31 hours 14 min Over continuous W Over continuous W Running draw (1000 W) exceeds 600 W continuous AC rating. Prefill
Jackery Explorer 300 Plus 288 Wh · 300 W AC · 600 W surge 19 min 0.31 hours 15 min Over continuous W Over continuous W Running draw (1000 W) exceeds 300 W continuous AC rating. Prefill
BLUETTI Elite 30 V2 288 Wh · 600 W AC 19 min 0.31 hours 15 min Over continuous W Over continuous W Running draw (1000 W) exceeds 600 W continuous AC rating. Prefill
Anker SOLIX C300 288 Wh · 300 W AC · 600 W surge 19 min 0.31 hours 15 min Over continuous W Over continuous W Running draw (1000 W) exceeds 300 W continuous AC rating. Prefill
Pecron E300LFP 288 Wh · 600 W AC 19 min 0.31 hours 15 min Over continuous W Over continuous W Running draw (1000 W) exceeds 600 W continuous AC rating. Prefill
Jackery Explorer 300 293 Wh · 300 W AC · 500 W surge 19 min 0.32 hours 15 min Over continuous W Over continuous W Running draw (1000 W) exceeds 300 W continuous AC rating. Prefill
Goal Zero Yeti 300 296.96 Wh · 350 W AC · 600 W surge 19 min 0.32 hours 15 min Over continuous W Over continuous W Running draw (1000 W) exceeds 350 W continuous AC rating. Prefill
BLUETTI AC60 403.2 Wh · 600 W AC 26 min 0.44 hours 20 min Over continuous W Over continuous W Running draw (1000 W) exceeds 600 W continuous AC rating. Prefill
BLUETTI AC50B 448 Wh · 700 W AC 29 min 0.49 hours 23 min Over continuous W Over continuous W Running draw (1000 W) exceeds 700 W continuous AC rating. Prefill
Goal Zero Yeti 500X 497 Wh · 300 W AC · 1,200 W surge 33 min 0.54 hours 25 min Over continuous W Over continuous W Running draw (1000 W) exceeds 300 W continuous AC rating. Prefill
Goal Zero Yeti 500 499.2 Wh · 500 W AC · 1,000 W surge 33 min 0.55 hours 25 min Over continuous W Over continuous W Running draw (1000 W) exceeds 500 W continuous AC rating. Prefill
EcoFlow RIVER 2 Max 512 Wh · 500 W AC 34 min 0.56 hours 26 min Over continuous W Over continuous W Running draw (1000 W) exceeds 500 W continuous AC rating. Prefill
Anker 535 PowerHouse 512 Wh · 500 W AC 34 min 0.56 hours 26 min Over continuous W Over continuous W Running draw (1000 W) exceeds 500 W continuous AC rating. Prefill
Jackery Explorer 500 518 Wh · 500 W AC 34 min 0.57 hours 26 min Over continuous W Over continuous W Running draw (1000 W) exceeds 500 W continuous AC rating. Prefill
EcoFlow RIVER 3 Max 572 Wh · 600 W AC · 1,200 W surge 38 min 0.63 hours 29 min Over continuous W Over continuous W Running draw (1000 W) exceeds 600 W continuous AC rating. Prefill
Pecron E500LFP 576 Wh · 600 W AC 38 min 0.63 hours 29 min Over continuous W Over continuous W Running draw (1000 W) exceeds 600 W continuous AC rating. Prefill
Jackery Explorer 600 v2 640 Wh · 500 W AC · 1,000 W surge 42 min 0.70 hours 32 min Over continuous W Over continuous W Running draw (1000 W) exceeds 500 W continuous AC rating. Prefill
Goal Zero Yeti 700 677.37 Wh · 600 W AC · 1,000 W surge 44 min 0.74 hours 34 min Over continuous W Over continuous W Running draw (1000 W) exceeds 600 W continuous AC rating. Prefill
BLUETTI AC70 768 Wh · 1,000 W AC · 1,500 W surge 50 min 0.84 hours 39 min Over continuous W Surge too low Published surge (1,500 W) is below cited 2,500 W startup. Prefill
EcoFlow RIVER 2 Pro 768 Wh · 800 W AC 50 min 0.84 hours 39 min Over continuous W Over continuous W Running draw (1000 W) exceeds 800 W continuous AC rating. Prefill
BLUETTI AC70P 864 Wh · 1,000 W AC · 2,000 W surge 57 min 0.94 hours 44 min Over continuous W Surge too low Published surge (2,000 W) is below cited 2,500 W startup. Prefill

Worked station examples

Calculated with the exact same shared runtime function as the interactive tool above.

EcoFlow

EcoFlow DELTA 2 Max

2 h 14 min (2.24 hours) on 12k ASHRAE · 1,000 W (2,500 W est. surge) — Fits spec.

2,048 Wh, 2,400 W continuous AC, and 4,800 W surge run a 1,000 W portable AC for ~2h 14m (at 70% duty).

Jackery

Jackery Explorer 5000 Plus

4 h 14 min (4.24 hours) on 14k ASHRAE · 1,300 W (3,250 W est. surge) — Fits spec.

5,040 Wh, 7,200 W continuous AC, and 14,400 W surge run a 1,300 W unit for ~4h 12m (at 70% duty).

Common questions

Can a 1,000 Wh power station run a portable air conditioner?
Only briefly. If the station clears the 2,500–3,250 W compressor startup surge, a ~1,000 Wh pack provides roughly 50–65 minutes of runtime on a 1,000 W unit at 70% duty cycle.
Why do inverter portable ACs work better on battery stations?
Variable-speed inverter compressors ramp up smoothly instead of slamming the inverter with a 3× locked-rotor surge, and throttle down once the room cools.

Relevant stations, comparisons & guides

Check full manufacturer spec sheets, compare models side-by-side, or read the broader use-case guide.

EcoFlow

EcoFlow DELTA 2 Max

  • Capacity:2,048 Wh
  • Continuous AC:2,400 W
  • Weight:≈ 50.7 lb
  • Chemistry:LFP

Est. 12k ASHRAE · 1,000 W (2,500 W est. surge): 2 h 14 min (Fits spec)

EcoFlow DELTA 2 Max: 2,048 Wh, LFP, 2,400 W continuous AC, 4,800 W surge.

EcoFlow

EcoFlow DELTA Pro 3

  • Capacity:4,096 Wh
  • Continuous AC:4,000 W
  • Weight:113.5 lb
  • Chemistry:LFP

Est. 12k ASHRAE · 1,000 W (2,500 W est. surge): 4 h 29 min (Fits spec)

EcoFlow DELTA Pro 3: 4,096 Wh, LFP (LiFePO4), 4,000 W continuous AC, 8,000 W surge.

Jackery

Jackery Explorer 5000 Plus

  • Capacity:5,040 Wh
  • Continuous AC:7,200 W
  • Weight:134.5 lb
  • Chemistry:LiFePO4

Est. 12k ASHRAE · 1,000 W (2,500 W est. surge): 5 h 30 min (Fits spec)

Jackery Explorer 5000 Plus: 5,040 Wh, LiFePO4, 7,200 W continuous AC, 14,400 W surge.

Sources & methodology

Appliance specifications checked November 22, 2026. Station check dates appear on the linked model pages.

How runtime and surge checks are computed: Methodology.