Appliance runtime · surge check · checked November 22, 2026

Will a portable power station run a sump pump? Surge watts and outage runtime

Most compact power stations fail on sump pumps before capacity even matters: an inductive pump motor demands 1,300–4,100 W for a split second at startup, and resistive-boost modes like X-Boost or Power Lifting do not cover motor surge.

Cited wattages & electrical specs

Every figure below links to the manufacturer or official reference page where it was read on November 22, 2026.

Cited electrical specifications for Sump pump
Specification Published value Notes Source
Zoeller Model 53 (3/10 HP / 1/3 HP class) 115 V, 60 Hz · 4.8–9.7 A full load (~1,116 VA max) Zoeller 50-Series technical datasheet FM2778 (also listed on the Model 53 product page); shaded-pole motor draws up to 9.7 A running. zoellerpumps.com checked 2026-11-22
1/3 HP sump pump running & starting watts ~800 W running · 1,300–2,900 W starting Jackery's sump-pump sizing table lists 800 W running and 1,300–2,900 W startup surge for 1/3 HP units. jackery.com checked 2026-11-22
Zoeller Model 98 (1/2 HP) 115 V, 60 Hz · 4.7–9.4 A (PSC motor) Zoeller FM2779 technical datasheet (Model 98 product page); permanent split capacitor (PSC) motors often draw lower running amps than older shaded-pole designs. zoellerpumps.com checked 2026-11-22
Zoeller Model 53 & 98 product sheets Manufacturer model reference Primary product catalog entries for Model 53 (https://zoellerpumps.com/product/model-53-sump-pump/) and Model 98 (https://zoellerpumps.com/product/model-98-sump-pump/). zoellerpumps.com checked 2026-11-22
1/2 HP sump pump running & starting watts ~1,050 W running · 2,150–4,100 W starting Jackery's sump-pump sizing table lists 1,050 W running and 2,150–4,100 W startup surge for 1/2 HP units. jackery.com checked 2026-11-22

How our estimate works & what to watch

Same defaults as the runtime calculator: 90% depth of discharge, 85% AC inverter efficiency, 95% DC efficiency.

Surge rating vs. resistive-boost marketing The brief electrical spike when an electric motor or compressor starts from a stop. Resistive-boost modes (X-Boost, Power Lifting, SurgePad) are not motor surge ratings and are excluded from surge pass/fail checks.

Stations whose published surge rating sits below the pump's startup wattage are hard-flagged in the table below. Features like EcoFlow X-Boost, BLUETTI Power Lifting, or Anker SurgePad lower voltage for resistive heaters—they are NOT motor startup surge ratings and are excluded from surge checks.

Continuous pumping hours vs. hours of outage The share of each hour an appliance actually draws its running watts (for example, 35% means a fridge compressor runs about 21 minutes per hour on average). Changing duty cycle scales runtime proportionally.

The table lists continuous pumping hours (100% duty) because storm inflow varies wildly. If a 2,048 Wh station delivers ~1.9 hours of continuous pumping and your float switch runs 10 minutes per hour (≈17% duty), that equals roughly 11 hours of storm coverage—less inverter standby draw while waiting.

When surge is unstated on the spec sheet Inverter efficiency is the share of battery energy that reaches an AC appliance. The default is 85%. Real efficiency changes with load and temperature, and most spec sheets in this dataset do not publish a single efficiency number.

Some manufacturers publish a continuous AC rating without a separate AC surge wattage. Those models are flagged 'Surge unstated' rather than assumed to pass—verify locked-rotor amp compatibility before relying on them in a storm.

Prefilled Sump pump runtime calculator

Preloaded with our cited sump pump baseline. Switch scenarios, pick any catalog station, or enter the watts from your own appliance label.

Open in full calculator

Station

Nameplate 960 Wh. Continuous 1500 W. Surge 3000 W. Spec sheet.

Assumptions

Depth of discharge is the share of nameplate watt-hours treated as usable. The default is 90% because spec sheets usually publish nameplate capacity, not the watt-hours the battery management system delivers on every cycle. Change it if you want a more conservative or more optimistic plan.

Loads

Planning baseline from cited specs. Replace watts, duty %, and startup W with the label on your own unit.

1/3 HP sump pump

How long each catalog station runs it (85 models)

Computed with the shared calculator formula (90% DoD, 85% AC / 95% DC efficiency). 33 of 85 models meet the primary scenario's published output and port checks.

Showing all 85 models
Catalog runtime table for Sump pump
Station 1/3 HP (800 W / 2,900 W surge) Runtime shows continuous pumping hours (100% duty). Uses the 2,900 W upper cited startup figure for 1/3 HP pumps so marginal stations are flagged. Formula: (Wh × 90%) ÷ (W × duty ÷ 85%). 1/2 HP (1,050 W / 4,100 W surge) Runtime shows continuous pumping hours (100% duty). Uses the 4,100 W upper cited startup figure for 1/2 HP pumps. Compatibility The brief electrical spike when an electric motor or compressor starts from a stop. Resistive-boost modes (X-Boost, Power Lifting, SurgePad) are not motor surge ratings and are excluded from surge pass/fail checks. Calculator
Pecron F1000LFP 960 Wh · 1,500 W AC · 3,000 W surge 55 min 0.92 hours 42 min Surge too low Fits spec Published 3,000 W surge clears 2,900 W startup. Prefill
Goal Zero Yeti 1000X 997 Wh · 1,500 W AC · 3,000 W surge 57 min 0.95 hours 44 min Surge too low Fits spec Published 3,000 W surge clears 2,900 W startup. Prefill
Goal Zero Yeti 1000 998.4 Wh · 2,000 W AC · 3,600 W surge 57 min 0.95 hours 44 min Surge too low Fits spec Published 3,600 W surge clears 2,900 W startup. Prefill
EcoFlow DELTA 3 Plus 1,024 Wh · 1,800 W AC · 3,600 W surge 59 min 0.98 hours 45 min Surge too low Fits spec Published 3,600 W surge clears 2,900 W startup. Prefill
Anker SOLIX C1000 Gen 2 1,024 Wh · 2,000 W AC · 3,000 W surge 59 min 0.98 hours 45 min Surge too low Fits spec Published 3,000 W surge clears 2,900 W startup. Prefill
DJI Power 1000 1,024 Wh · 2,200 W AC · 4,400 W surge 59 min 0.98 hours 45 min 0.75 hours Fits spec Published 4,400 W surge clears 2,900 W startup. Prefill
Pecron E1000LFP 1,024 Wh · 1,800 W AC · 3,000 W surge 59 min 0.98 hours 45 min Surge too low Fits spec Published 3,000 W surge clears 2,900 W startup. Prefill
EcoFlow DELTA 3 Classic 1,024 Wh · 1,800 W AC · 3,600 W surge 59 min 0.98 hours 45 min Surge too low Fits spec Published 3,600 W surge clears 2,900 W startup. Prefill
Jackery Explorer 1000 v2 1,070 Wh · 1,500 W AC · 3,000 W surge 1 h 1 min 1.02 hours 47 min Surge too low Fits spec Published 3,000 W surge clears 2,900 W startup. Prefill
Jackery Explorer 1000 Plus 1,264.64 Wh · 2,000 W AC · 4,000 W surge 1 h 13 min 1.21 hours 55 min Surge too low Fits spec Published 4,000 W surge clears 2,900 W startup. Prefill
Goal Zero Yeti 1500 1,505.28 Wh · 2,000 W AC · 3,600 W surge 1 h 26 min 1.44 hours 1 h 6 min Surge too low Fits spec Published 3,600 W surge clears 2,900 W startup. Prefill
Pecron E1500LFP 1,536 Wh · 2,200 W AC · 4,400 W surge 1 h 28 min 1.47 hours 1 h 7 min 1.12 hours Fits spec Published 4,400 W surge clears 2,900 W startup. Prefill
Jackery Explorer 1500 v2 1,536 Wh · 2,000 W AC · 4,000 W surge 1 h 28 min 1.47 hours 1 h 7 min Surge too low Fits spec Published 4,000 W surge clears 2,900 W startup. Prefill
Anker SOLIX S2000 2,010 Wh · 1,500 W AC · 3,000 W surge 1 h 55 min 1.92 hours 1 h 28 min Surge too low Fits spec Published 3,000 W surge clears 2,900 W startup. Prefill
Jackery Explorer 2000 v2 2,042 Wh · 2,200 W AC · 4,400 W surge 1 h 57 min 1.95 hours 1 h 29 min 1.49 hours Fits spec Published 4,400 W surge clears 2,900 W startup. Prefill
Jackery Explorer 2000 Plus 2,042.8 Wh · 3,000 W AC · 6,000 W surge 1 h 57 min 1.95 hours 1 h 29 min 1.49 hours Fits spec Published 6,000 W surge clears 2,900 W startup. Prefill
EcoFlow DELTA 2 Max 2,048 Wh · 2,400 W AC · 4,800 W surge 1 h 58 min 1.96 hours 1 h 30 min 1.49 hours Fits spec Published 4,800 W surge clears 2,900 W startup. Prefill
Anker SOLIX C2000 Gen 2 2,048 Wh · 2,400 W AC · 4,000 W surge 1 h 58 min 1.96 hours 1 h 30 min Surge too low Fits spec Published 4,000 W surge clears 2,900 W startup. Prefill
EcoFlow DELTA 3 Max 2,048 Wh · 2,400 W AC · 4,800 W surge 1 h 58 min 1.96 hours 1 h 30 min 1.49 hours Fits spec Published 4,800 W surge clears 2,900 W startup. Prefill
EcoFlow DELTA 3 Max Plus 2,048 Wh · 3,000 W AC · 6,000 W surge 1 h 58 min 1.96 hours 1 h 30 min 1.49 hours Fits spec Published 6,000 W surge clears 2,900 W startup. Prefill
Pecron E2400LFP 2,048 Wh · 2,400 W AC · 4,000 W surge 1 h 58 min 1.96 hours 1 h 30 min Surge too low Fits spec Published 4,000 W surge clears 2,900 W startup. Prefill
BLUETTI Elite 300 3,014.4 Wh · 2,400 W AC · 4,800 W surge 2 h 53 min 2.88 hours 2 h 12 min 2.20 hours Fits spec Published 4,800 W surge clears 2,900 W startup. Prefill
Goal Zero Yeti 3000X 3,032 Wh · 2,000 W AC · 3,500 W surge 2 h 54 min 2.90 hours 2 h 13 min Surge too low Fits spec Published 3,500 W surge clears 2,900 W startup. Prefill
Pecron E3600LFP 3,072 Wh · 3,600 W AC · 7,000 W surge 2 h 56 min 2.94 hours 2 h 14 min 2.24 hours Fits spec Published 7,000 W surge clears 2,900 W startup. Prefill
EcoFlow DELTA 3 Ultra 3,072 Wh · 3,600 W AC · 7,200 W surge 2 h 56 min 2.94 hours 2 h 14 min 2.24 hours Fits spec Published 7,200 W surge clears 2,900 W startup. Prefill
Jackery HomePower 3000 3,072 Wh · 3,600 W AC · 7,200 W surge 2 h 56 min 2.94 hours 2 h 14 min 2.24 hours Fits spec Published 7,200 W surge clears 2,900 W startup. Prefill
Pecron F3000LFP 3,072 Wh · 3,600 W AC · 4,500 W surge 2 h 56 min 2.94 hours 2 h 14 min 2.24 hours Fits spec Published 4,500 W surge clears 2,900 W startup. Prefill
Jackery HomePower 3600 Plus 3,584 Wh · 3,600 W AC · 7,200 W surge 3 h 26 min 3.43 hours 2 h 37 min 2.61 hours Fits spec Published 7,200 W surge clears 2,900 W startup. Prefill
EcoFlow DELTA Pro 3,600 Wh · 3,600 W AC · 7,200 W surge 3 h 27 min 3.44 hours 2 h 37 min 2.62 hours Fits spec Published 7,200 W surge clears 2,900 W startup. Prefill
Anker SOLIX F3800 Plus 3,840 Wh · 6,000 W AC · 9,000 W surge 3 h 40 min 3.67 hours 2 h 48 min 2.80 hours Fits spec Published 9,000 W surge clears 2,900 W startup. Prefill
EcoFlow DELTA Pro 3 4,096 Wh · 4,000 W AC · 8,000 W surge 3 h 55 min 3.92 hours 2 h 59 min 2.98 hours Fits spec Published 8,000 W surge clears 2,900 W startup. Prefill
Jackery Explorer 5000 Plus 5,040 Wh · 7,200 W AC · 14,400 W surge 4 h 49 min 4.82 hours 3 h 40 min 3.67 hours Fits spec Published 14,400 W surge clears 2,900 W startup. Prefill
Goal Zero Yeti 6000X 6,071 Wh · 2,000 W AC · 3,500 W surge 5 h 48 min 5.81 hours 4 h 25 min Surge too low Fits spec Published 3,500 W surge clears 2,900 W startup. Prefill
DJI Power 500 512 Wh · 1,000 W AC 29 min 0.49 hours 22 min Over continuous W Surge unstated Surge rating not published (needs ~2,900 W startup). Prefill
Anker SOLIX C800 Plus 768 Wh · 1,200 W AC 44 min 0.73 hours 34 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). 1,600 W resistive boost is not motor surge. Prefill
EcoFlow RIVER 2 Pro 768 Wh · 800 W AC 44 min 0.73 hours 34 min Over continuous W Surge unstated Surge rating not published (needs ~2,900 W startup). 1,600 W resistive boost is not motor surge. Prefill
BLUETTI Elite 100 V2 1,024 Wh · 1,800 W AC 59 min 0.98 hours 45 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). 2,700 W resistive boost is not motor surge. Prefill
DJI Power 1000 V2 1,024 Wh · 2,600 W AC 59 min 0.98 hours 45 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). Prefill
EcoFlow DELTA 3 1,024 Wh · 1,800 W AC 59 min 0.98 hours 45 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). Prefill
Jackery HomePower 1000 Plus v2 1,024 Wh · 1,800 W AC 59 min 0.98 hours 45 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). Prefill
Anker SOLIX C1000 1,056 Wh · 1,800 W AC 1 h 1 min 1.01 hours 46 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). 2,400 W resistive boost is not motor surge. Prefill
Anker 757 PowerHouse 1,229 Wh · 1,500 W AC 1 h 11 min 1.18 hours 54 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). Prefill
Jackery Explorer 1500 Ultra 1,536 Wh · 1,800 W AC 1 h 28 min 1.47 hours 1 h 7 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). Prefill
BLUETTI AC240 1,536 Wh · 2,400 W AC 1 h 28 min 1.47 hours 1 h 7 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). 3,600 W resistive boost is not motor surge. Prefill
Jackery HomePower 2000 Plus v2 2,048 Wh · 2,400 W AC 1 h 58 min 1.96 hours 1 h 30 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). Prefill
BLUETTI AC200L 2,048 Wh · 2,400 W AC 1 h 58 min 1.96 hours 1 h 30 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). 3,600 W resistive boost is not motor surge. Prefill
Anker SOLIX F2000 2,048 Wh · 2,400 W AC 1 h 58 min 1.96 hours 1 h 30 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). 3,600 W resistive boost is not motor surge. Prefill
DJI Power 2000 2,048 Wh · 3,000 W AC 1 h 58 min 1.96 hours 1 h 30 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). Prefill
BLUETTI AC200MAX 2,048 Wh · 2,200 W AC 1 h 58 min 1.96 hours 1 h 30 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). Prefill
BLUETTI Elite 200 V2 2,073.6 Wh · 2,600 W AC 1 h 59 min 1.98 hours 1 h 31 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). 3,900 W resistive boost is not motor surge. Prefill
BLUETTI Apex 300 2,764.8 Wh · 3,840 W AC 2 h 39 min 2.64 hours 2 h 1 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). Prefill
Anker SOLIX F3000 3,072 Wh · 3,600 W AC 2 h 56 min 2.94 hours 2 h 14 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). Prefill
Anker SOLIX F3800 3,840 Wh · 6,000 W AC 3 h 40 min 3.67 hours 2 h 48 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). Prefill
Pecron E3800LFP 3,840 Wh · 4,200 W AC 3 h 40 min 3.67 hours 2 h 48 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). Prefill
Pecron F5000LFP 5,120 Wh · 7,200 W AC 4 h 54 min 4.90 hours 3 h 44 min Surge unstated Surge unstated Surge rating not published (needs ~2,900 W startup). Prefill
BLUETTI AC2A 204.8 Wh · 300 W AC 12 min 0.20 hours 9 min Over continuous W Over continuous W Running draw (800 W) exceeds 300 W continuous AC rating. Prefill
EcoFlow RIVER 3 245 Wh · 300 W AC 14 min 0.23 hours 11 min Over continuous W Over continuous W Running draw (800 W) exceeds 300 W continuous AC rating. Prefill
EcoFlow RIVER 2 256 Wh · 300 W AC 15 min 0.24 hours 11 min Over continuous W Over continuous W Running draw (800 W) exceeds 300 W continuous AC rating. Prefill
Jackery Explorer 240 v2 256 Wh · 300 W AC · 600 W surge 15 min 0.24 hours 11 min Over continuous W Over continuous W Running draw (800 W) exceeds 300 W continuous AC rating. Prefill
Anker 521 PowerHouse 256 Wh · 200 W AC 15 min 0.24 hours 11 min Over continuous W Over continuous W Running draw (800 W) exceeds 200 W continuous AC rating. Prefill
BLUETTI EB3A 268.8 Wh · 600 W AC · 1,200 W surge 15 min 0.26 hours 12 min Over continuous W Over continuous W Running draw (800 W) exceeds 600 W continuous AC rating. Prefill
EcoFlow RIVER 3 Plus 286 Wh · 600 W AC 16 min 0.27 hours 13 min Over continuous W Over continuous W Running draw (800 W) exceeds 600 W continuous AC rating. Prefill
Jackery Explorer 300 Plus 288 Wh · 300 W AC · 600 W surge 17 min 0.28 hours 13 min Over continuous W Over continuous W Running draw (800 W) exceeds 300 W continuous AC rating. Prefill
BLUETTI Elite 30 V2 288 Wh · 600 W AC 17 min 0.28 hours 13 min Over continuous W Over continuous W Running draw (800 W) exceeds 600 W continuous AC rating. Prefill
Anker SOLIX C300 288 Wh · 300 W AC · 600 W surge 17 min 0.28 hours 13 min Over continuous W Over continuous W Running draw (800 W) exceeds 300 W continuous AC rating. Prefill
Pecron E300LFP 288 Wh · 600 W AC 17 min 0.28 hours 13 min Over continuous W Over continuous W Running draw (800 W) exceeds 600 W continuous AC rating. Prefill
Jackery Explorer 300 293 Wh · 300 W AC · 500 W surge 17 min 0.28 hours 13 min Over continuous W Over continuous W Running draw (800 W) exceeds 300 W continuous AC rating. Prefill
Goal Zero Yeti 300 296.96 Wh · 350 W AC · 600 W surge 17 min 0.28 hours 13 min Over continuous W Over continuous W Running draw (800 W) exceeds 350 W continuous AC rating. Prefill
BLUETTI AC60 403.2 Wh · 600 W AC 23 min 0.39 hours 18 min Over continuous W Over continuous W Running draw (800 W) exceeds 600 W continuous AC rating. Prefill
BLUETTI AC50B 448 Wh · 700 W AC 26 min 0.43 hours 20 min Over continuous W Over continuous W Running draw (800 W) exceeds 700 W continuous AC rating. Prefill
Goal Zero Yeti 500X 497 Wh · 300 W AC · 1,200 W surge 29 min 0.48 hours 22 min Over continuous W Over continuous W Running draw (800 W) exceeds 300 W continuous AC rating. Prefill
Goal Zero Yeti 500 499.2 Wh · 500 W AC · 1,000 W surge 29 min 0.48 hours 22 min Over continuous W Over continuous W Running draw (800 W) exceeds 500 W continuous AC rating. Prefill
EcoFlow RIVER 2 Max 512 Wh · 500 W AC 29 min 0.49 hours 22 min Over continuous W Over continuous W Running draw (800 W) exceeds 500 W continuous AC rating. Prefill
Anker 535 PowerHouse 512 Wh · 500 W AC 29 min 0.49 hours 22 min Over continuous W Over continuous W Running draw (800 W) exceeds 500 W continuous AC rating. Prefill
Jackery Explorer 500 518 Wh · 500 W AC 30 min 0.50 hours 23 min Over continuous W Over continuous W Running draw (800 W) exceeds 500 W continuous AC rating. Prefill
EcoFlow RIVER 3 Max 572 Wh · 600 W AC · 1,200 W surge 33 min 0.55 hours 25 min Over continuous W Over continuous W Running draw (800 W) exceeds 600 W continuous AC rating. Prefill
Pecron E500LFP 576 Wh · 600 W AC 33 min 0.55 hours 25 min Over continuous W Over continuous W Running draw (800 W) exceeds 600 W continuous AC rating. Prefill
Jackery Explorer 600 v2 640 Wh · 500 W AC · 1,000 W surge 37 min 0.61 hours 28 min Over continuous W Over continuous W Running draw (800 W) exceeds 500 W continuous AC rating. Prefill
Goal Zero Yeti 700 677.37 Wh · 600 W AC · 1,000 W surge 39 min 0.65 hours 30 min Over continuous W Over continuous W Running draw (800 W) exceeds 600 W continuous AC rating. Prefill
BLUETTI AC70 768 Wh · 1,000 W AC · 1,500 W surge 44 min 0.73 hours 34 min Over continuous W Surge too low Published surge (1,500 W) is below cited 2,900 W startup. Prefill
BLUETTI AC70P 864 Wh · 1,000 W AC · 2,000 W surge 50 min 0.83 hours 38 min Over continuous W Surge too low Published surge (2,000 W) is below cited 2,900 W startup. Prefill
EcoFlow DELTA 2 1,024 Wh · 1,800 W AC · 2,700 W surge 59 min 0.98 hours 45 min Surge too low Surge too low Published surge (2,700 W) is below cited 2,900 W startup. Prefill
BLUETTI AC180 1,152 Wh · 1,800 W AC · 2,700 W surge 1 h 6 min 1.10 hours 50 min Surge too low Surge too low Published surge (2,700 W) is below cited 2,900 W startup. Prefill
BLUETTI AC180P 1,440 Wh · 1,800 W AC · 2,700 W surge 1 h 23 min 1.38 hours 1 h 3 min Surge too low Surge too low Published surge (2,700 W) is below cited 2,900 W startup. Prefill
Anker SOLIX F2600 2,560 Wh · 2,400 W AC · 2,800 W surge 2 h 27 min 2.45 hours 1 h 52 min Surge too low Surge too low Published surge (2,800 W) is below cited 2,900 W startup. Prefill

Common questions

Will a 300 W or 350 W power station run a sump pump?
No. Even a 1/3 HP pump draws around 800 W while running and 1,300–2,900 W at motor startup, far exceeding both the continuous AC rating and surge limit of 300–600 W compact packs.
How do I check my own pump's startup requirement?
Check the pump's nameplate or spec sheet for Volts, Full Load Amps (FLA), and Locked Rotor Amps (LRA). Multiplying Volts × LRA gives the worst-case starting VA; permanent split capacitor (PSC) motors typically start with much lower surge than older shaded-pole motors.

Relevant stations, comparisons & guides

Check full manufacturer spec sheets, compare models side-by-side, or read the broader use-case guide.

EcoFlow

EcoFlow DELTA 3 Plus

  • Capacity:1,024 Wh
  • Continuous AC:1,800 W
  • Weight:27.6 lb
  • Chemistry:LFP

Est. 1/3 HP (800 W / 2,900 W surge): 59 min (Fits spec)

EcoFlow DELTA 3 Plus: 1,024 Wh, LFP (LiFePO4), 1,800 W continuous AC, 3,600 W surge.

Jackery

Jackery Explorer 2000 v2

  • Capacity:2,042 Wh
  • Continuous AC:2,200 W
  • Weight:39.5 lb
  • Chemistry:LiFePO4

Est. 1/3 HP (800 W / 2,900 W surge): 1 h 57 min (Fits spec)

Jackery Explorer 2000 v2: 2,042 Wh, LiFePO4, 2,200 W continuous AC, 4,400 W surge.

Pecron

Pecron E3600LFP

  • Capacity:3,072 Wh
  • Continuous AC:3,600 W
  • Weight:79 lb
  • Chemistry:LiFePO4

Est. 1/3 HP (800 W / 2,900 W surge): 2 h 56 min (Fits spec)

Pecron E3600LFP: 3,072 Wh, LiFePO4, 3,600 W continuous AC, 7,000 W surge.

Sources & methodology

Appliance specifications checked November 22, 2026. Station check dates appear on the linked model pages.

How runtime and surge checks are computed: Methodology.